Yaskawa CIMR-PU2A0081 — изменение частоты и параметры управления в режиме привода [110/548]

Превью страниц Страница 110 / 548
Yaskawa CIMR-PU2A0040 [110/548] U1 02 0 0hz u1 03 0 0a
Figure 4.7 illustrates how to change the frequency reference from F 0.00 (0 Hz) to F 6.00 (6 Hz) while in the Drive Mode.
This example assumes the drive is set to LOCAL.
ESC
F1
F2
Frequency reference
display at power up
Press to select LOCAL
Press until the frequency
reference changes to 006.00 Hz
left right
- MODE -
U1-01= 0.00Hz
U1-02= 0.00Hz
U1-03= 0.00A
DRV
FREF (OPR)
Rdy
JOG FWD FWD/REV
LSEQ
LREF
- MODE -
U1-01= 6.00Hz
U1-02= 0.00Hz
U1-03= 0.00A
DRV
FREF (OPR)
Rdy
JOG FWD FWD/REV
LSEQ
LREF
-MONITR-
FREF (d1-01)
U1-01= 000.00Hz
“0.00Hz”
DRV
FWD
Rdy
-MONITR-
FREF (d1-01)
U1-01= 006.00Hz
“0.00Hz”
DRV
FWD
Rdy
-MONITR-
FREF (d1-01)
U1-01= 006.00Hz
(0.00 ~ 60.00)
“0.00Hz”
DRV
FWD
Rdy
Entry Accepted
(0.00 ~ 60.00)
(0.00 ~ 60.00)
Figure 4.7 Setting the Frequency Reference while in the Drive Mode
Note: The drive will not accept a change
to the frequency reference until the ENTER key is pressed after the frequency reference is entered. This
feature prevents accidental setting of the frequency reference. To have the drive accept changes to the frequency reference as soon as changes
are made without requiring the ENTER key, set o2-05 to 1.
n
Programming Mode Details
The following actions are possible in the Programming Mode:
Parameter Setting Mode: Access and edit all parameter settings.
Verify Menu: View a list of parameters that have been changed from the default values.
Setup Group: Access a list of commonly used parameters to simplify setup (Refer to Simplified Setup Using the Setup
Groups on page 113).
Auto-Tuning Mode: Automatically calculate and set motor parameters to optimize drive performance.
u
Changing Parameter Settings or Values
This example explains changing C1-02 (Deceleration Time 1) from 10.0 seconds (default) to 20.0 seconds.
Step Display/Result
1. Turn on the power to the drive. The initial display appears.
- MODE -
U1-01= 0.00Hz
U1-02= 0.00Hz
U1-03= 0.00A
DRV
FREF (OPR)
Rdy
JOG FWD FWD/REV
LSEQ
LREF
2.
Press
or until the Parameter Setting Mode screen appears.
HELP
- MODE - PRG
DATA
Programming
FWD
3.
Press
to enter the parameter menu tree.
-PRMSET-
Initialization
Select Language
PRG
FWD
A1-00= 0
4.
Press
or to select the C parameter group.
-PRMSET-
Basic Setup
Accel Time 1
PRG
FWD
C1-01= 10.0 sec
5.
Press
two times.
-PRMSET-
Accel/Decel
Accel Time 1
PRG
FWD
C1-01= 10.0 sec
-PRMSET-
C1-01= 10.0Sec
(0.0~6000.0)
“10.0 sec”
PRG
Accel Time 1
FWD
4.3 The Drive, Programming, and Clock Adjustment Modes
110
YASKAWA SIEP YAIP1U 01A AC Drive - P1000 Technical Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Содержание

2656

Узнайте, как изменить частоту и настроить параметры управления в режиме привода. Подробные инструкции и советы по оптимизации работы устройства.