Gigabyte MZ31-AR0 (rev. 2.x) [115/134] 10 2 firmware image location

Gigabyte MZ31-AR0 (rev. 2.x) [115/134] 10 2 firmware image location
- 115 - Gigabyte Server Management Console
mkdir /tftpboot
chmod -R 777 /tftpboot
chown -R nobody /tftpboot
5. Toreceivetheleyouhavetotouchtheleandgivepermissiontoaccessbyallusers
>touch<DIR>/conf.bak
>chmod777<DIR>/conf.bak
6. Even after all this step has been done and still facing error of timeout:
a) Checkwith/etc/xinetd.d/tftpleanduncommenttheEOF(Removethe‘#’
before the EOF alone).
b) Restart the server.
2-10-2 Firmware Image Location
ThispageisusedtocongurermwareimageintotheBMC.
To open Firmware Image Location, click Maintenance > Firmware Image Location from the
menu bar.
A sample screenshot of Firmware Image Location page is shown below.
The various options of Image Transfer Protocol are given below.
Image Location Type:TypeoflocationtotransferthermwareimageintotheBMCeitherWeb
Upload during Flash or TFTP Server.
TFTP Server Address:Addressoftheserverwherethermwareimageisstored.
Note: The Server supports both IPv4 and IPv6 addresses
IP Address made of 4 numbers separated by dots as in “xxx.xxx.xxx.xxx”.
Each number ranges from 0 to 255.
First number must not be 0.
IPv6 Address made of 8 groups of 4 Hexadecimal digits separated by colon as in
“xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx.”