Gigabyte MZ31-AR0 (rev. 2.x) [56/134] Procedure

Gigabyte W291-Z00 (rev. A00) [56/134] Procedure
Gigabyte Server Management Console - 56 -
Event Filters
APEFimplementationisrecommended toprovide atleast40entriesintheeventltertable.
Asubsetoftheseentriesshouldbepre-conguredforcommonsystemfailureevents,suchas
over-temperature, power system failure, fan failure events, etc. Remaining entries can be made
available for ‘OEM’ or System Management Software configured events. Note that individual
entriescanbetaggedasbeingreservedforsystemuse-sothisratioofpre¬conguredentries
torun-timecongurableentriescanbereallocatedifnecessary.
TheeldsofPlatformEventFiltersTabareexplainedbelow.
ThispagecontainsPre-congured40EventswithPEFIDs.
Procedure
1. ClicktheEventFilterssectiontoconguretheeventltersintheavailableslots.
2. To Add an Event Filter entry, select a free section to open the Event Filter entry page. A
samplescreenshotofEventFilterCongurationpageisshownbelow.