Haier AS09SH1ERA Сервис мануал онлайн [25/109] 614391

Содержание

Haier Function control Serial No Temperature scope Frequency limitation 1 Wh_c 28 Max_hz1 46HZ 2 Wh_c 32 Max_hz2 72HZ 3 Wh_c 40 Max_hz3 80HZ 4 Wh_c 48 Max_hz4 65HZ 5 Wh_c 48 Max_hz5 50HZ Remarks the above are not only the maximum frequency limitations of the complete appliance which are affected by the environment but also the maximum ability limitation of the system When the starting ability is not the maximum its maximum frequency limitation is calculated by the following equations The frequency limitation which is affected by the temperature and under the condition of actual ability the actual running system ability the maximum frequency which is limited by the temperature and under the condition of maximum ability the maximum designing ability of the system T ATi Pi Pi Ti Tst_i the setting temperature Tnh_i the indoor environment temperature Pi i the ability of the indoor unit Refrigeration dehumidification T 1 1 2 3 4 50 70 100 120 140 T 1 1 2 3 4 The percentage of the 50 70 100 140 160 The percentage of the rated frequency P Heating mode rated frequency P The indoor setting airflow speed The percentage of the rated frequency Ki Breeze Low Medium High Strong Quiet 65 70 90 100 180 65 Healthy airflow 65 K Z Ki Pi Pi The calculation of the actual output frequency when there is no healthy airflow F F ED rated frequency xPxK When the healthy airflow has been set F F ED xPxK airflow speed xK healthy airflow Notes When refrigerating it is needed to satisfy F MIN d compressor s Min_hz F F M A X d compressor s Max_hz When heating it is needed to satisfy F M IN r compressor s Min_hz F F M A X r compressor s Max_hz Haier Domestic Air Conditioner 22