Haier AS09SH1ERA [50/109] Operation
Содержание
- Service manaul p.1
- Dc inverter free match s series p.1
- Wall mounted type p.1
- Model no as09 12sh1era p.1
- U09 12eh1 era p.1
- Table of contents p.2
- Model name explanation p.4
- Introduction p.4
- Safety cautions p.4
- Warning p.5
- Introduction p.5
- Domestic air conditioner p.5
- Caution in repair p.5
- Warning p.6
- Introduction p.6
- Domestic air conditioner p.6
- Cautions regarding products after repair p.6
- Warning p.7
- Caution p.7
- Introduction p.7
- Inspection after repair p.7
- Domestic air conditioner p.7
- Domestic air conditioner p.8
- Caution p.8
- Î caution caution p.8
- Warning warning p.8
- Using icons list p.8
- Using icons p.8
- T note note p.8
- Reference p.8
- Introduction p.8
- Icon type of information description p.8
- List of fuctions p.9
- Specifications p.10
- Domestic air conditioner p.10
- As09sh1era 1u09eh1 era as12sh1era 1u12eh1era p.10
- Conversion formulae p.11
- Snb130fgym2 snb130fgym2 p.11
- Domestic air conditioner p.11
- Cooling heating piping length p.11
- W 52 52 p.11
- U09eh1era 1u12eh1era p.11
- The data are based on the conditions shown in the table below p.11
- Specifications p.11
- Indoor unit connectors p.12
- Outdoor unit p.13
- Connectors p.13
- Lo о o p.15
- Main functions and control specification of indoor unit p.16
- Funcitions and control p.16
- Dehumidifying mode p.16
- Cooling operation mode p.16
- Automatic operation p.16
- Heating operation mode p.17
- Dormant operation p.18
- Air refreshing p.18
- Timing p.18
- Strength operation p.18
- Mute operation p.18
- Urgent on off input p.19
- Low load protection control p.19
- High load protection control p.19
- Abnormal operation of indoor system p.19
- Malfunction list resume p.20
- Single indoor system operation p.20
- Power cut compensation p.20
- Fixed frequency operation p.20
- Abnormality confirmation approaches p.20
- Time cutting function p.21
- Test program p.21
- Ifp optional function p.22
- Temp display p.23
- Degree heating maintaining p.23
- The starting of compressor p.24
- The speeds of increasing or decreasing the frequency of the compressor p.24
- The operation frequency of outdoor unit and its control p.24
- The operation frequency control of compressor p.24
- The calculation of the compressor s frequency p.24
- Main functions and control specification of outdoor unit p.24
- The outdoor fan control when refrigerating or dehumidifying p.26
- The outdoor fan control when heating p.26
- The outdoor fan control exchange fan p.26
- The control of the outdoor electronic expansion valve eev p.26
- Ttc high temperature preventing protection p.27
- Tc high temperature preventing control of the indoor heating unit p.27
- Protection function p.27
- Four way control p.27
- Anti freezing protection of the indoor heat exchanger p.28
- The protection function of ac current p.28
- The control of preventing the over current of the compressor p.28
- The frequency limitation of modification rate p.29
- Temperature protection of the outdoor refrigerating coil p.29
- Function of main thermistor p.30
- B exhaust temperature sensor c indoor heat exchange sensor p.30
- A outdoor suction temperature sensor p.30
- Value of thermistor 5 intdoor unit p.31
- Room sensor and pipe sensor p.31
- R25 c 10kq 3 b25 c 50 c 3700k 3 p.31
- Haier ____________ p.31
- R25 c 10kq 3 p.34
- Outdoor unit p.34
- B25 c 50 c 3700k 3 p.34
- Ambient sensor suction sensor defrosting sensor p.34
- Domestic air conditioner p.35
- Function control p.35
- Function control p.36
- Domestic air conditioner p.36
- Function control p.37
- Domestic air conditioner p.37
- Function and control p.38
- Domestic air conditioner p.38
- Discharging sensor p.38
- C 50kq 3 p.38
- 80 c 4450к 3 p.38
- Function and control p.39
- Domestic air conditioner p.39
- Function and control p.40
- Domestic air conditioner p.40
- Function and control p.41
- Domestic air conditioner p.41
- System configuration p.42
- Instruction p.42
- Remote controller p.43
- Parts and functions p.43
- Outdoor unit p.43
- Indoor unit p.43
- Operation p.44
- Loading of the battery p.44
- Clock set p.44
- Smart operation cool heat and dry operation p.45
- Operation p.45
- Select tempsetting fan operation swing operation p.46
- Operation p.46
- Notice p.47
- Health operation health airflow operation p.47
- Health airflow function p.47
- The setting of p.47
- The health airflow function p.47
- The cancel of p.47
- Press health button p.47
- Operation p.47
- Power soft operation timer operation p.48
- Operation p.48
- Operation p.49
- Comfortable sleep p.49
- Operation p.50
- Operation p.51
- Fresh operation emergency operation and test operation p.51
- For smart use of the air conditioner p.51
- Cautions p.52
- A warning p.52
- A caution p.52
- Trouble shooting p.53
- Cautions p.53
- Before asking for service check the following first p.53
- Symptom check item details of measure p.54
- Service diagnosis p.54
- Problem symptoms and measures p.54
- Caution for diagnosis p.54
- Error codes and description p.55
- Thermistor or related abnormality p.56
- Indoor ac fan motor malfunction p.57
- Indoor dc fan motor malfunction p.59
- How to check fan motor dc p.59
- Outdoor dc fan motor fault p.61
- Ipm protection p.62
- The communication fault between ipm and outdoor pcb p.64
- Be sure to turn off power switch before connect or disconnect connector or p.65
- Malfunction p.65
- Else parts damage may be caused p.65
- Conditions p.65
- Troubleshooting p.65
- Overheat protection for discharge temperature p.65
- Method of p.65
- Faulty thermistor p.65
- Faulty pcb p.65
- Electronic expansion valve defective p.65
- Detection p.65
- Faulty eeprom p.66
- Else parts damage may be caused p.66
- Eeprom abnormal p.66
- Detection p.66
- Conditions p.66
- Be sure to turn off power switch before connect or disconnect connector or p.66
- Troubleshooting p.66
- Method of p.66
- Malfunction p.66
- Faulty pcb p.66
- Faulty eeprom data p.66
- Communication error between the indoor and outdoor units p.67
- An abnormal voltage rise or fall is detected by specified voltage checking p.69
- Supply voltage not as specified p.69
- Power supply over or under voltage fault p.69
- Microcomputer p.69
- Method of p.69
- Malfunction p.69
- Detection circuit p.69
- Detection p.69
- Conditions p.69
- An voltage signal is feedback from the voltage detection circuit to the p.69
- Troubleshooting be p.69
- To turn off power switch before connect or disconnect connector or p.69
- Loop of the station detect error p.70
- Over current of the compressor p.71
- High work intense protection p.72
- Mismatching between indoor and outdoor units p.73
- Short of refrigerant p.74
- Method of p.75
- Malfunction p.75
- High work intense protection p.75
- Detection p.75
- Conditions p.75
- Installation manual of room air conditioner p.77
- Installation p.77
- Drawing for the installation of indoor and outdoor units p.77
- Domestic air conditioner p.77
- Preparation p.77
- Unloading of indoor unit body p.78
- Selection of pipe p.78
- Removing the wiring cover p.78
- Rear piping p.78
- Other direction piping p.78
- Making a hole on the wall and fitting the piping hole cover p.78
- Left left rear piping p.78
- Installation of the indoor unit p.78
- Installation p.78
- Indoor unit p.78
- Fixing the indoor unit body p.78
- Fitting of the mounting plate and positioning of the wall hole p.78
- Drawing of pipe p.78
- Domestic air conditioner p.78
- When the mounting plate is fixed side bar and lintel о connecting the indoor outdoor electric cable p.78
- When the mounting plate is first fixed p.78
- Accessory parts p.78
- When connecting the cable after installing the indoor unit p.78
- Purging method to use vacuum pump p.79
- Outdoor unit p.79
- Installation of outdoor unit p.79
- Installation p.79
- Domestic air conditioner p.79
- Connection of pipes p.79
- Connection p.79
- Attaching drain elbow optional p.79
- Caution p.80
- Removal procedure p.81
- Removal of front panel p.81
- Indoor unit p.81
- Removal of filter and blade p.83
- Removal of front grill p.84
- Removal of drain pan p.86
- Removal of display assembly p.87
- Removal of vertical blades and swing motor p.88
- Removal of electrical box p.89
- Removal of heat exchanger p.90
- Removal of fan rotor and fan motor p.92
- Removal procedure p.93
- Removal of outdoor panel p.93
- Outdoor unit p.93
- Domestic air conditioner p.93
- Loosen the screws of the panel p.95
- Removal of electrical box p.96
- Removal of fan and fan motor p.97
- Removal of fan motor bracket and partition p.98
- Domestic air conditioner p.99
- Removal procedure p.99
- Removal of compressor and heat exchange p.100
- В1им11111 p.101
- Fil il m p.101
- Piping diagrams p.102
- Heating mode p.102
- Cooling mode p.102
- Appendix p.102
- Outdoor wtrtng diagram p.104
- Outdoor unit 01 p.104
- Control board circuit diagrams p.105
- Control board circuit diagrams p.106
- Module board circuit diagram p.108
- Sincere forever p.109
- Haier group p.109
Похожие устройства
-
Haier HME 09 TW03Инструкция по эксплуатации -
Haier HME 09 AW03Инструкция по эксплуатации -
Haier HSE 20 TW03Инструкция по эксплуатации -
Haier HSE 20 AW03Инструкция по эксплуатации -
Haier HSE 17 TW03Инструкция по эксплуатации -
Haier HSE 17 AW03Инструкция по эксплуатации -
Haier HSE 16 TW03Инструкция по эксплуатации -
Haier HSE 16 AW03Инструкция по эксплуатации -
Haier HSE 12 TW03Инструкция по эксплуатации -
Haier HSE 12 TD03Инструкция по эксплуатации -
Haier HSE 12 AH03Инструкция по эксплуатации -
Haier HSE 9 TW03Инструкция по эксплуатации
Haier Introduction Operation I ECO Operation iFP Operation The movement of people in the room can be sensed which can improve the air adjustment efficiency Automatic adjusting with the environmental temperature running with power saving Press iFP button lii is displayed on the remote controller Press ECONOMY button E51 and A is displayed on the is displayed on the remote display board unit will unrin controller unit will run in iFP mode ECONOMY operation A Every time the button is pressed display changes as follows Press ECONOMY button For Remote controller twice press ECONOMY BLANK EVADE disappears the operation stops LQJ Detect the location of the human body adjust the wind swing blow the location where the body is FOLLOW EVADE Detect the location of the human body adjust the wind swing avoid the location where the body is When several people are located at different positions or one person is moving in different areas no matter whether the wind is blowing or not the wind will automatically swing and blow to multi areas the wind direction adjustment will be delayed it cannot be deflected suddenly while detecting The power saving function only works under the cooling heating or dehumidifying mode after the power saving function is set press the sharp mute sleep or smart key to exit the power saving function In iFP FOLLOW and EVADE operation mode Press 1 button the unit will not operate mode Press jS button the operation stops The human body sensor is used to detect if the infrared ray is changing It may be inaccurate in the following conditions The human body keeps still when reading or watching TV etc or is blocked by barriers like screen cabinet or glass The person is wearing very thick clothes or the person is lying or sleeping A pet is moving frequently or the wind is blowing the curtains or something in the room is swinging frequently Haier After the power saving is set the host machine will automatically adjust the setting temperature and automatically control the switch of the compressor which may be inconsistent with the user s setting The power saving function is more effective after the air conditioning has been running for a long time more than 2 hours 47 Domestic air conditioner
![Haier AS09SH1ERA [50/109] Operation](/views2/1812078/page50/bg32.png)