Haier Service Diagnosis 7 Service Diagnosis 7 1 Caution for Diagnosis The operation lamp flashes when any of the following errors is detected I When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions disabling equipment operation 2 When a signal transmission error occurs between the indoor and outdoor units In either case conduct the diagnostic procedure described in the following pages 7 2 Problem Symptoms and Measures Symptom Check Item Details of Measure None of the units Check the power supply Check to make sure that the rated voltage is supplied operates Check the indoor PCB Check to make sure that the indoor PCB is broken Operation Check the power supply A power failure of 2 to 10 cycles can stop air conditioner sometimes stops Equipment operates but does not cool or does not heat only for heat pump operation Check for faulty operation Set of temperatures of the liquid side connection pipes of the the electronic expansion valve the units to cooling operation and compare the connection section among rooms to check the opening and closing operation of the electronic expansion valves of the individual units Diagnosis by service port pressure and Check for insufficient gas operating current Large operating noise and vibrations Haiei Check the installation condition Check to make sure that the required spaces for installation specified in the Technical Guide etc are provided 51 Domestic air conditioner