Haier AS09SH1ERA — проверка модуля IPM в кондиционерах: пошаговое руководство [63/109]

Содержание

Haiei Functions and control Check the IPM module method Disconnect the compressor harness connector from the outdoor unit PCB To disengage the connector press the protrusion on the connector Then measure resistance between P and N and the U V and W terminals of the compressor connector with a multi tester Evaluate the measurement results for a pass fail judgment N terminal of tester P for digital tester P UVW P uvw P terminal of tester N for digital tester uvw P UVW P Normal resistance Several kQ to several MQ Unacceptable resistance Short 0 Q or open Haier Domestic Air Conditioner 60