LEO 6XRP18/24-18.5 — инструкции по использованию водонепроницаемой и изоляционной ленты [7/10]
![LEO 6XRS17/7-4 [7/10] Connection of the copper core cable heat](/views2/1819901/page7/bg7.png)
Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11.
waterproof tape should cover more than 10mm of the heat shrink tubing
on both the start and end sides. The waterproof tape should be
elongated by pulling in 200% before wrapping and apply as per normal
wrapping tape.
(5)
Use the waterproof tape to bind that three-wrapped wire core
together. The waterproof tape should be elongated by pulling in 200%
and should cover more than 50mm of the cable rubber coating on both
the start and end sides.
(6)
Cover the wrapped cable again with the electrical insulation tape,
which should cover the waterproof tape fully. As shown:
1.
Connection of the Copper Core Cable Heat
shrink tubing Copper Core Cable
2.
Attachment of the Heat-shrink Tubing
Heat-shrink Tubing
3.
Wrapping the Waterproof Tape
4.
Wrapping the Insulation Tape
1..5
Selection of cable
:
Motor Power
(kW)
Cable Standard
4×1
4×1.5
4×2.5
4×4
4×6
4×10
4×16
4×25
Cable length(m)
Single
-Phase
0.37
55
80
130
0.55
35
55
90
140
0.75
25
40
65
105
160
1.1
20
30
50
75
115
190
1.5
22
36
60
90
145
230
2.2
25
40
60
100
165
T h r e e
-Phase
0.37
280
0.55
210
315
0.75
165
240
1.1
120
180
285
1.5
90
135
225
360
2.2
65
400
165
255
390
3.0
45
65
110
180
255
420
4.0
35
50
85
135
195
330
520
5.5
42
70
110
165
270
430
7.5
80
130
200
320
585
Waterproof Tape
Insulation Tape
Содержание
- Instruction manual p.1
- Borehole pump p.1
- Congratulations on your purchase of a leo borehole pump p.2
- Conditions of use p.3
- Descriptions of model specification and performance p.3
- General lntroduction p.3
- A well p.4
- Pressure value i p.4
- Calculation of pump total head formula p.4
- Requirements in the process of pumping p.4
- Is pump head p.4
- Head of pump base p.4
- H head loss in the pump pipe inside the well refer to the table below p.4
- Dynamic water leve p.4
- Condition of deep well p.4
- To the p.4
- Pump bas p.4
- H total head for the whole unit m p.4
- H h h v2 h p.4
- Well diameter and well depth p.4
- Water output and guarantee of water source p.4
- Vertical distanc p.4
- Static water level and dynamic water level of wen p.4
- Selection of pump p.4
- Structure description p.5
- Acquaer ltd h 4900 fehérgyarmat szatmári út 11 p.5
- This deep well submersible pump consists of pump working part pump power part submersible motor pipe part gate valve and control box etc connecting pump with motor with the shaft coupling to work under water see the figure below for its structure p.5
- Installation use and maintenance p.6
- Connection of the copper core cable heat p.7
- Attachment of the heat shrink tubing p.7
- Insulation tape p.7
- Heat shrink tubing p.7
- Acquaer ltd h 4900 fehérgyarmat szatmári út 11 p.7
- Wrapping the waterproof tape p.7
- Wrapping the insulation tape p.7
- Waterproof tape p.7
- Shrink tubing copper core cable p.7
- Motor is too low or tripping of the earth leakage protector p.10
- Control box p.10
- Symptoms main causes correction p.10
- Contact p.10
- Undersized cable if p.10
- Troubleshooting p.10
- The hot resistance of the p.10
- So use a bigger diameter cable p.10
- Choose a suitable p.10
- Check to see if the p.10
- Check to see if it is p.10
- Caused by an p.10
- A suitable control p.10
- There is a phase failure or a poor p.10
Похожие устройства
-
LEO 6XRP18/33-26Сертификат -
LEO 6XRP18/33-26Каталог -
LEO 6XRP18/33-26Инструкция по эксплуатации -
LEO 6XRP18/28-22Сертификат -
LEO 6XRP18/28-22Каталог -
LEO 6XRP18/28-22Инструкция по эксплуатации -
LEO 6XRP18/24-18.5Сертификат -
LEO 6XRP18/24-18.5Каталог -
LEO 6XRP18/19-15Сертификат -
LEO 6XRP18/19-15Каталог -
LEO 6XRP18/19-15Инструкция по эксплуатации -
LEO 6XRP18/17-13Сертификат
Узнайте, как правильно использовать водонепроницаемую и изоляционную ленту для защиты кабелей. Подробные инструкции и советы по обмотке и соединению.