3
WP
G
a) WPG b) WPG.S
Fig.1. Structure of water pump group
1 – tree-way valve with actuator, 2- pump, 3 – thermomanometer, 4- ball valve, 5 – ball valve with filter, 6 – casing
Fig.2. showing the simple example of application with the Air Handling unit and control elements.
Fig.2. Operation diagram with full WPG (a), and simple WPG.S (b)
b)
B1 – supply temperature sensor
VFD – frequency converter
T S2F – anti frost thermostat
B3 – external temperature sensor
1Y1 – damper actuator
ΔP – pressure guard
S3F – back water temperature sensor
Y1 – 3-way valve actuator
M1 – fan motor
M2 – pump motor
1 - casing
2 - thermomanometer
3 – circulation pump
4 - filter
5 – 3-way valve with actuator
a)
Содержание
- Water pump group p.1
- Contents p.2
- Max water temp c p.5
- Max current a p.5
- Lc wc hc inch dn l w h p.5
- Ip voltage p.5
- Foam casing type p.5
- Female thread diameter p.5
- Circuit casing dimension mm connection diameter circuit set dimension mm p.5
- Ambient temp c p.5
- Type mass kg voltage p max p.5
- Additional information for the elements of the group can find in the suppliers manuals p.5
- Technical parameters p.5
- Table technical data p.5
- Table dimension and connection diameter p.5
- Pump circuit type p.5
- Pump 3 way valve actuator p.5
- Overload protection ip p.5
- Max work pressure bar p.5
- The below characteristic concerning to the clean water the pumps groups may be used in heating systems containing glycol based anti freeze with corrosion inhibitors up to a maximum of 50 solution depending on the type of glycol the mixture and the liquid temperature the viscosity will increase with water as medium this will influence the pressure loss of the system as well as the efficiency performance and load of the pump p.6
- Pump groups characteristic p.6
- Fig characteristics of water pump groups p.6
- When loosening the air venting de blocking screw be aware of hot spraying water when loosening the air venting de blocking screw be aware of hot spraying water p.10
- Operation and maintenance start up of the pump do not start the pump until the system has been filled with liquid and vented being self venting the rotor can does not require venting before start up air inside the pump will be transported by the medium into the system during the first minutes after pump start up the system cannot be vented through the pump as the pump is self venting it does not need to be vented before start up however it is recommended to vent pumps installed in systems where the pumped medium is very dirty as well as after service of the pump the screw may be loosened to check if the system has been vented completely p.10
- Operating the pumps 25 6 and 25 8 p.10
- Operating the pump 25 12 operating panel p.11
- Display that shows the actual consumption power in watt 2 indicate lighting areas in automatic night mode 3 button to start the automatic night mode 4 button to select pump settings 5 automatically run and display light area 6 indicate seven lighting areas set in the pump p.11
- Trouble shooting p.12
Похожие устройства
-
VTS WPG.S - 25-12 - 16 EСертификат -
VTS WPG.S - 25-12 - 16 EИнструкция по эксплуатации -
VTS WPG - 25-12 - 16 EСертификат -
VTS WPG - 25-12 - 16 EИнструкция по эксплуатации -
VTS WPG.S - 25-08 - 16 EСертификат -
VTS WPG.S - 25-08 - 16 EИнструкция по эксплуатации -
VTS WPG - 25-08 - 16 EСертификат -
VTS WPG - 25-08 - 16 EИнструкция по эксплуатации -
VTS WPG.S - 25-08 - 10 EСертификат -
VTS WPG.S - 25-08 - 10 EИнструкция по эксплуатации -
VTS WPG - 25-08 - 10 EСертификат -
VTS WPG - 25-08 - 10 EИнструкция по эксплуатации