if this system is moved from a cold location to a warmer location,
condensation may form on the inside; wait for approximately an hour before
powering.
check system supply voltage, frequency and wattage correspond to the
mains electrical supply
always disconnect the system from the power supply before proceeding
with any type of maintenance and or repair work
do not use this system as a safety device
for repairs and information concerning this system refer to your local sales
outlet
2 USER INTERFACE
2.1 Preliminary instructions
There are two working modes:
“on” (the system is powered and a cycle is running )
“stand-by” (the system is powered but a cycle is not running )
“off” (the system is not powered)
If the power supply is unexpectedly interrupted during a timer controlled chilling
cycle, the moment power is restored the chilling cycle continues from the moment it
stopped (maximum error margin 10 minutes).
If the power supply is unexpectedly interrupted during a temperature controlled
chilling cycle, when power is restored the cycle restarts from the beginning of cycle.
If the power supply is unexpectedly interrupted during storage, when power is
restored storage mode continues.
If the power supply is interrupted with the blast chiller in stand-by mode
, when power is restored the chiller returns to stand-by.
2.2 Display
When “on” and during normal functioning, the following information is displayed:
remaining cycle time for timer controlled blast chilling if blast chilling
the temperature detected by the needle probe if running a blast chilling
cycle
chiller temperature when running a storage cycle.
With the chiller in “stand-by” during regular functioning, the internal chiller
temperature is displayed for ½ a second every 3 seconds.
2.3 Defrosting and evaporator fan
The function managed by relay K2 is subject to parameter u0
if u0=0 the function managed by relay K2 is defrosting (electrical
defrosting; the evaporator fan is not managed)
if u0=1 the function managed by relay K2 is the evaporator fan (defrosting
with compressor off)