Accesstyle MS20K100W Руководство по эксплуатации онлайн [39/44] 808097

Accesstyle MS20K100W Руководство по эксплуатации онлайн [39/44] 808097
39
check your wall socket and the fuse in your meter box.
If both the wall socket and the fuse are functioning properly,
CONTACT YOUR NEAREST SERVICE CENTER APPROVED.
SERVICING SAFEGUARDS
CAUTION: MICROWAVE RADIATION
1.
The high voltage capacitor remains charge after
disconnection; short the negative terminal of H. V capacitor
to the oven chassis (use a screwdriver) to discharge before
touching.
2. During servicing below listed parts are liable to be removed
and give access to potentials above 250V to earth.
Magnetron
High voltage transformer
High voltage capacitor
High voltage diode
High voltage fuse
3. The following conditions may cause undue microwave
exposure during servicing.
Improper tting of magnetron;
Improper matching of door interlock, door hinge and
door;
Improper tting of switch support;
Door, door seal or enclosure has been damaged.