0407
Blowing minus
Blowing plus
Air volume level display
F03
Timing automatic clean setting
(version 1.0) Working interface
U00
Operation:
Place or fix static eliminator ac ion fan in a stable working environment, connect the power
cord to the power interface on the host.
Under the main menu, short press " " key to enter automatic clean menu.
(factory default: automatic clean per 8 hours )
Short press " " or " " key to set the timing automatic clean time.
(Sett range: t01~999 hours)
Wait for 5 seconds after set, the system will automatically save the setting, or press " "
to save the setting and enter next menu.
Turn on the power switch, the screen displays the version number, air volume level, and the
indicator light flashes blue, after the cleaning brush starts to work for 3-5 seconds, the static
eliminator ac ion fan will enter normal operation state and the indicator light will display
as green.
04/
Operation instruction
Air volume adjustment:
Under the main menu, short press " " or " " key, adjust the appropriate air volume
level according to the work requirements. (Air volume range: F01-F05, F01 minimum air volume
F05 maximum air volume)
Menu setting
Timing automatic clean setting
It is recommended that the distance between the static eliminator ac ion fan and the
workplace between 30cm and 90cm. If the static electricity need to be neutralized quickly,
the recommended distance is 15cm.
Under working, try to make the ion wind cover a large area of the work place. The direction
of the ion wind can be adjusted by tilting the fan.
Adjust angle of static eliminator ac ion fan:
The orientation of the air outlet can be adjusted according to the operating environment,
with 10° as one gear and 0~265° air outlet adjustable.
According to the use environment, the ion fan bracket supports placed on the table or hung
vertically.
Desktop Hang up