Ryobi ONE+ R18AC-0 5133004540 Инструкция к Ryobi ONE+ R18AC-0 5133004540 онлайн [7/288] 816066
![Ryobi ONE+ R18AC-0 5133004540 Инструкция к Ryobi ONE+ R18AC-0 5133004540 онлайн [7/288] 816066](/views2/2048552/page7/bg7.png)
WARNING
Always remove the battery pack from the tool when you
DUHDVVHPEOLQJSDUWVPDNLQJDGMXVWPHQWVFOHDQLQJRU
ZKHQ WKH SURGXFW LV QRW LQ XVH 5HPRYLQJWKHEDWWHU\
pack will prevent accidental starting that could cause
VHULRXVSHUVRQDOLQMXU\
WARNING
Do not use in an environment which is dusty or otherwise
contaminated. Using the air compressor in this type of
environment may cause damage to the product.
Adjusting the air pressure
See page 197.
1. 0DNHVXUHWKHRQRIIVZLWFKLVLQWKH2))2SRVLWLRQ
and the battery pack is removed.
2. Connect the battery pack to the product.
3. Press the
RQRIIVZLWFKWRWKH21,SRVLWLRQ
Pull the pressure regulator knob outward to enable
DGMXVWPHQW
5. 5RWDWHSUHVVXUHUHJXODWRUNQREWRWKHGHVLUHGSUHVVXUH
Turning the knob clockwise increases air pressure
at the outlet. Turning counterclockwise reduces air
pressure at the outlet. Push the pressure regulator knob
WRGLVDEOHDGMXVWPHQW
6. Following all safety precautions in this manual and the
manufacturer’s instructions in the air tool manual, you
may now proceed to use your air-powered tool.
WARNING
$LU SRZHUHG WRROV PD\ UHTXLUH PRUH DLU FRQVXPSWLRQ
than this air compressor is capable of providing. Check
the tool manual to avoid damage to the tool or risk of
SHUVRQDOLQMXU\
7. Control the amount of air flow with the pressure
regulator knob. Turning the knob fully counterclockwise
will completely stop the flow of air.
NOTE: Always use the minimum amount of pressure
necessary for your application. Using a higher pressure
than needed will drain air from the tank more rapidly
DQGFDXVHWKHXQLWWRF\FOHRQPRUHIUHTXHQWO\
8. To turn the air compressor off, press the power switch to
the OFF (O) position.
NOTE: When the compressor is in the ON (I) position,
the air compressor will automatically turn on when the
designated tank air pressure drops below the preset
pressure limit. It will also shut off again when the
desired pressure is reached.
WARNING
Never exceed the air tool’s pressure rating as
recommended by the manufacturer. When using this
DLUFRPSUHVVRUDVDQLQÀDWLRQGHYLFHDOZD\VIROORZWKH
PD[LPXPLQÀDWLRQJXLGHOLQHVVWDWHGE\WKHPDQXIDFWXUHU
RIWKHLWHPEHLQJLQÀDWHG
WARNING
$OZD\V HQVXUH WKH RQRII VZLWFK LV LQ WKH 2)) 2
position and the regulator pressure gauge reads zero
before changing air tools or disconnecting the hose from
the air outlet. Failure to do so could result in possible
VHULRXVSHUVRQDOLQMXU\
9. When finished, always drain the tank and remove the
battery pack. Never leave the product operating or
connected to the battery pack.
DRAINING THE AIR TANK
See page 198.
To prevent tank corrosion and keep moisture out of the air
tank, the air tank of the compressor should be drained daily.
To drain the air tank:
1. 0DNHVXUHWKHRQRIIVZLWFKLVLQWKH2))2SRVLWLRQ
2. 5HPRYHWKHEDWWHU\SDFN
3. Pull the ring on the pressure relief valve until the Tank
SUHVVXUHJDXJHUHDGVOHVVWKDQEDU36,
5HOHDVHWKHULQJ
5. Turn the drain valve lever counterclockwise to drain the
moisture.
NOTE: Condensate is a polluting material and should
be disposed of in compliance with local regulations.
6. Turn the drain valve lever clockwise to close the drain
valve.
RESET BUTTON
When current into the air compressor motor exceeds the
VSHFL¿HGXQLWWKHDLUFRPSUHVVRUZLOODXWRPDWLFDOO\VKXWRII
To reset the air compressor:
1. 5HPRYHWKHEDWWHU\SDFN
2. Turn off the product.
3. Wait three minutes for the motor to cool.
Press the reset button.
5. Connect the battery pack to the product.
6. Turn on the product.
CHANGING A COUPLER
See pages 199.
1. 0DNHVXUHWKHRQRIIVZLWFKLVLQWKH2))2SRVLWLRQ
2. 5HPRYHWKHEDWWHU\SDFN
3. Pull the ring on the pressure relief valve until the Tank
SUHVVXUHJDXJHUHDGVOHVVWKDQEDU36,
5HOHDVHWKHULQJ
5. Using a wrench, loosen and remove the coupler by
turning counterclockwise.
6. Using a wrench, install a new coupler and tighten in a
clockwise direction.
TRANSPORTATION AND STORAGE
See pages 200-201.
1. 0DNHVXUHWKHRQRIIVZLWFKLVLQWKH2))2SRVLWLRQ
2. 5HPRYHWKHEDWWHU\SDFN
3. 5XQWKHDLUWRROWRUHOLHYHWKHDLUSUHVVXUHLQWKHKRVH
WKHQUHPRYHWKHDLUKRVHDQGWKHDLUWRRO5HOHDVHWKH
air by pulling the pressure relief valve.
Drain water from the tank as instructed in “Draining the
5 English |
EN
FR
DE
ES
IT
NL
PT
DA
SV
FI
NO
RU
PL
CS
HU
RO
LV
LT
ET
HR
SL
SK
BG
UK
TR
EL
Похожие устройства
- Remeza СБ4/Ф-500.LT100 Д 7065490 Инструкция к товару
- Remeza СБ 4/С- 90 W95-6 SPE390E бензиновый, со стартером 1164920 Инструкция к товару
- VIATTO CH5L 56511 Инструкция по эксплуатации
- Schneider Airsystems unm 210-10-25 wxof 1129741050 Инструкция
- BAMBI VT200D Инструкция к компрессору BAMBI VT300
- BAMBI VT250D Инструкция к компрессору BAMBI VT300
- BAMBI VT300D Инструкция к компрессору BAMBI VT300
- BAMBI VT400D Инструкция к компрессору BAMBI VT300
- Кратон AC-350-50-DDV 3 01 01 036 Инструкция
- Кратон AC-350-50-DDV 3 01 01 036 Схема сборки Компрессор с прямой передачей Кратон AC-350-50-DDV
- Кратон AC-350-50-DDV 3 01 01 036 Инструкция по эксплуатации
- Кратон AC-360-100-DDV 3 01 01 037 Инструкция Кратон Компрессор с прямой передачей AC-360-100-DDV
- Кратон AC-360-100-DDV 3 01 01 037 Схема сборки Кратон Компрессор с прямой передачей AC-360-100-DDV
- Бежецк АСО КТ-16 2808 Инструкция
- VERTON Air AC-100/420V вертикальный бак, масляный ременной 420л/мин,100л,12бар, 2,5кВт, 230В, рапид 01.12210.13370 Инструкция по эксплуатации
- VERTON Air AC-150/700R 01.5985.12199 Инструкция по эксплуатации
- VERTON Air AC-300/1020R 01.5985.12201 Инструкция по эксплуатации
- ABAC MICRON 410-200 Инструкция к компрессору Abac MICRON 410-200
- ABAC MICRON.E 5.510-200 Инструкция к компрессору Abac MICRON 410-200
- FROSP бензиновый КВД 125/300 Honda GX160 5875 Инструкция по эксплуатации