MEAN WELL GST60A12-P1J Т02289318 Инструкция к товару онлайн [2/5] 826843

MEAN WELL GST60A12-P1J Т02289318 Инструкция к товару онлайн [2/5] 826843
SPECIFICATION
GST60A series
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.)
Note.3
OUTPUT
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS Note. 8
SAFETY &
EMC
(Note. 9)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GST60A05
GST60A05-P1J
GST60A07-P1J
GST60A09-P1J
GST60A12-P1J
GST60A15-P1J
GST60A18-P1J
GST60A24-P1J
GST60A48-P1J
7.5V
GST60A07
9V
GST60A09
12V
GST60A12
15V
GST60A15
18V
GST60A18
24V
GST60A24
48V
GST60A48
120mVp-p 120mVp-p 120mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±3.0% ±2.5%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±3.0% ±2.5%
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
85.5% 88.5% 89% 89.5% 89.5% 89.5% 90.5% 92%
1.4A / 115VAC 1A / 230VAC
Cold start 35A / 115AC 65A / 230VAC
0.75mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
709.7K hrs min. MIL-HDBK-217F(25 )
-30 ~ +70 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
±℃0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
125*50*31.5mm (L*W*H)
0.305Kg; 40pcs/13.02Kg/1.05CUFT
CONNECTOR
PLUG
CABLE
See page 4~5 ; Other type available by customer requested
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
8. The demand for Malaysia safety is processed with the order no. GST60A -SIRIM by request. Please contact MEAN WELL for details.
9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
6A 6A 6A 5A 4A 3.33A 2.5A 1.25A
0 ~ 6A 0 ~ 6A 0 ~ 6A 0 ~ 4A 0 ~ 3.33A 0 ~ 2.5A
0 ~ 1.25A
30W 45W 54W 60W
0 ~ 5A
60W 60W 60W 60W
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load
50ms / 230VAC 15ms / 115VAC at full load
7.8 ~ 10.2V 9.4 ~ 12.2V 12.6 ~ 16.2V 15.7 ~ 20.3V 18.9 ~ 24.3V 25.2 ~ 32.4V 50.4 ~ 64.8V
5.2 ~ 6.8V
See page 4~5 ; Other type available by customer requested
60WAC-DC High Reliability IndustrialAdaptor
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1 , BIS IS13252,,AS/NZS 60950.1
KC K60950-1, approvedEAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional)
EMC IMMUNITY
EMC EMISSION
Parameter
Standard
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN61000-3-2,GB9254
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11
>.95% dip 0 5 periods, 30% dip 25 periods,
95% interruptions 250 periods
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
μ
μ
File Name:GST60A-SPEC 2017-05-05
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
RF field
susceptibility
EFT bursts
Surge susceptibility
Level 4, 15KV air; Level 4, 8KV contact
Conducted susceptibility
Magnetic field
immunity
Voltage dips , interruption
Level 2, 3V/m
Level 3, 1KV/Line-Line , 2KV/Line-FG
Level 2, 3A/m
Level 2, 3V
Level 2, 1KV
Скачать