Искра для контакторов серии KNL43-KNL75 RC3-KNL УТ-00019708 Инструкция онлайн [11/84] 838389

Искра для накадных контакторов серии KNL22-KNL38 NDL3-40 УТ-00019699 Инструкция онлайн [11/84] 840071
3.000
10.000.000
170 215160
IEC/EN 60947-5-1, UL 508
CE, UL, CSA, EAC
45
35
4
°C
°C
mm
dB
op. c./h
op. c.
g
A
V
kV
V
Hz
A
A
A
U
i
U
imp
U
e
f
I
th
I
e
IP20
3
95 % relative humidity
-30 … +80
-20 … +60
-20 … +45
no limitation
2030 30
GENERALMAIN CIRCUIT
>17 V; >50 mA
690
6
690
25
50/60
20
20
Unit
Type
op. c./h
op. c./h
0.75 … 2.5
0.5 … 2.5
10
M3.5
PZ2
1.2
1.200
1.200
1.000.000
op. c.
S
2
mm
mm
Nm
4 / 0.25
A
I
e
6
4
2
1
U
c
U
c
U
c
f
85 ... 110
20 … 75 10 … 75
AC DC
1) 2) 3)
/
50/60
remote control with U
c
10
M3.5
PZ2
1.2
39/34
8.1/4 - / 3
- / 3
1015
1015
25 … 30
0.75 … 2.5
615 510 10 … 25
0.5 … 2.5
V
Hz
mm
Nm
VA/W
ms
2
mm
%
%
COIL
m
2000
1) 6,12,24,42,48,110/125,220/240,380/415,440/460,550 V 2) 6,12,24,42,48,110/125,220/240,380/415,440/460,500,690 V 3) 6,12,24,48,60,72,110,125,220,250 V
CONTACTORS - MINIATURE CONTACTOR RELAYS
K03C, K07C, K07CF, K07CX, K07CG, K07CGF, K07CGX
1
1-11
TECHNICAL DATA
Symbol
K03C
K07C
K07CF
K07CX
K07CG
K07CGF
K07CGX
Maximum operating frequency with no load
Mechanical endurance
Weight
Contact reliability
Maximum back-up fuse for short-circuit protection gL and gG:
coordination type 2
Rated insulation voltage
Rated impulse withstand voltage
Rated operational voltage
Rated frequency
Thermal current
Rated operational current for AC-1, AC-7a and AC-21
Standards
Approvals
Module width
Number of poles
Degree of protection
Pollution degree
Climatic conditions
Storage temperature
Number of contactors or switches side-by-side:
Ambient temperature:
<40 °C
open
(40 … 55) °C
closed
Noise level (operation)
Terminal capacity:
rigid (solid and stranded)
flexible
Length of removed wire insulation
Screw
Screw head
Tightening torque
Maximum operating frequency for AC-15
Maximum operating frequency for DC-13
Electrical endurance for AC-15
Rated operational current for DC-13:
1 pole … 24 V DC/110 V DC
Rated operational current for AC-15:
single-phase 230 V
single-phase 400 V
single-phase 500 V
single-phase 690 V
Range of control voltage for switch-on
Range of control voltage for drop out
Kind of voltage
Standard control voltages
Frequency of AC control voltage
Control mode
Coil consumption:
Delays:
Terminal capacity:
switch-on
make
rigid (solid and stranded)
operation
brake
flexible
Length of removed wire insulation
Screw
Screw head
Tightening torque
Maximum altitude
U and U is reduced for 1.2 % and I for 0.4 % for every additional 100 m
i e e

Похожие устройства

Скачать