Искра для накадных контакторов серии KNL22-KNL38 NDL3-40 УТ-00019699 Инструкция онлайн [9/84] 840071
![Искра для накадных контакторов серии KNL22-KNL38 NDL3-40 УТ-00019699 Инструкция онлайн [9/84] 840071](/views2/2058544/page9/bg9.png)
3.000
10.000.000
170 215 215 170
160
IEC/EN 60947-5-1, IEC 60947-4-1, UL 508
CE, UL, CSA, EAC
CE, EAC
45
35
4
°C
°C
mm
dB
op. c./h
op. c./h
op. c.
op. c./h
op. c./h
op. c.
g
W
A
V
kV
V
Hz
A
A
A
A
kW
kW
kW
HP
U
i
U
imp
U
e
f
I
th
I
e
I
e
I
e
P
e
P
e
P
e
P
e
IP20
3
95 % relative humidity
-30 … +80
-20 … +60
-20 … +45
no limitation
20 302030 30
MAIN CIRCUIT
>17 V; >50 mA
1.2
68
690
6
690
90.4 90.4
25
124 124
50/60
20
20
8.5
/
11.3
5
11.3
5
15.5 (11.3*)
5
15.5 (11.3*)
5
600
200.000
600
300
1.000.000
100.000
4.4
0.75
1/3
1.1
1/2 1/2 1/2 1/2
1.1 1.1 1.1
7.5
3
3.7 (3*) 3.7 (3*)
2
/
3/4
3
0.75
1.5 1.5 1.5 1.5
0.75 0.75 0.75
13
4
/
2
5.5
2.2
3 3 3 3
5.5
1.5
5 5 55
5.5
1.5
7.5
5.5
1.5
7.5
5.5
1.5
7.5
5.5
1.5
7.5
5.5
1.5
5.5
1.5
5.5
1.5
5.5
2.2
7.5 (5.5*)
2.2
7.5 (5.5*)
2.2
17.5
4
/
3
4
/
5
22
Symbol
Unit
Type
K03M
K07M
K07MF
K07MX
K07MG
K07MGF
K07MGX
K08MG K08M
op. c.
op. c.
U and U is reduced for 1.2 % and I for 0.4 % for every additional 100 m
i e e
m
2000
* It applies for AC-3e
CONTACTORS - MINIATURE CONTACTORS
K03M, K07M, K07MF, K07MX, K07MG, K07MGF, K07MGX, K08M, K08MG
1
1-9
TECHNICAL DATA
Maximum operating frequency with no load
Mechanical endurance
Standards
Approvals
Module width
Number of poles
Degree of protection
Pollution degree
Climatic conditions
Storage temperature
Number of contactors or switches side-by-side:
Ambient temperature:
<40 °C
open
(40 … 55) °C
closed
Noise level (operation)
GENERAL
Maximum altitude
Weight
Contact reliability
Power dissipation per pole
Overload current withstand capability - 10 s
Maximum back-up fuse for short-circuit protection gL and gG:
coordination type 2
Rated insulation voltage
Rated impulse withstand voltage
Rated operational voltage
Rated frequency
Thermal current
Rated operational current for AC-1, AC-7a and AC-21
Rated operational current for AC-3, AC-3e, AC-7b and AC-23 (at 400 V)
Rated operational current for AC-4 (at 400 V)
Maximum operating frequency for AC-1, AC-7a and AC-21
Electrical endurance for AC-1, AC-7a and AC-21
Maximum operating frequency for AC-3, AC-3e, AC-7b and AC-23
Maximum operating frequency for AC-4
Electrical endurance for AC-3, AC-3e, AC-7b and AC-23
Electrical endurance for AC-4
Operational power for AC-1, AC-7a and AC-21:
Operational power for AC-3, AC-3e, AC-7b and AC-23:
Operational power for AC-4:
Rated motor power according to standards UL and CSA:
single-phase 230 V
single-phase 230 V
single-phase 115 V
three-phase 230 V
three-phase 230 V
three-phase 230 V
single-phase 230 V
three-phase 400 V
three-phase 400 V
three-phase 400 V
three-phase 230 V
three-phase 500 V
three-phase 500 V
three-phase 500 V
three-phase 460 V
three-phase 690 V
three-phase 690 V
three-phase 690 V
three-phase 575 V
Похожие устройства
- KRASS 2921031SB Инструкция к товару
- KRASS 2921020SB Инструкция к товару
- KRASS 2921030SB Инструкция к товару
- Искра для накадных контакторов серии KNL43-KNL75 NDL4-04 УТ-00019701 Инструкция
- Рубин РЭ-АКБ1255 Перед использованием
- Спец ОГН-РУК1 Инструкция
- Спец ОГН-РУК8 Инструкция
- НПО ПУЛЬС 5701010100015 Инструкция
- НПО ПУЛЬС 5701010200011 Инструкция
- Русарсенал 741509597201 Инструкция по эксплуатации
- Русарсенал 741509597202 Инструкция по эксплуатации
- KRASS 2931005SB Инструкция к товару
- KRASS 2931006SB Инструкция к товару
- Рубин БКС 3x10 РЭ-БКС-3х10 Паспорт
- HEIBERG Dn10 DIN EN856 4SP/4SH, 3/8",W.P. 445 BAR, 100 м 0004Н10 сертификат
- HEIBERG Dn38 DIN EN853 2SN, 1-1/2",W.P.90 BAR, 40 м 0002Н38 сертификат
- ArTorq присоединение по стандарту DIN, APL-210N Страница каталога с технической информацией
- HEIBERG Dn08 DIN EN853 2SN, 5/16",W.P.350 BAR, 100 м 0002Н8 сертификат
- ArTorq присоединение по стандарту DIN, LS-2M00 Страница каталога с технической информацией
- Partex НФ-00000970-1 чертеж бака