Operating principle and illumination
Image creation system: objective (6), prism (7) and eyepiece (9). The
objective lens (6) magnifies a specimen (0), light rays pass through the prism
(7), refract at a 45° angle and create an image in the eyepiece. Total
magnification may be calculated by multiplying magnifications of the
eyepiece and the objective used.
Using the microscope
Getting started
Unpack the microscope and make sure all parts are available.
Move the stage to the lowermost position using the focusing knob and turn on the illumination or
adjust the reflector to evenly illuminate the specimen within the field of view.
Connect the microscope to A/C power using the A/C adapter.
Insert the eyepiece into the eyepiece tube.
Slowly adjust the illumination brightness, from dark to light. When you finish your observations,
always dim the illumination before unplugging the power cable.
If you need to change the light bulb, unplug your microscope first.
Illumination system: lamp (1), collector lens (2), diaphragm (3) and
condenser (4). Light emitted from the lamp (1) passes through the collector
lens (2) and illuminates the diaphragm (3). Then, the light is focused by the
condenser (4). This illumination system is used for observations of a
specimen (0) in transmitted light. You can also use a different type of
illumination (e.g. a reflector) for observations in reflected light.
Focusing
Place a specimen on the stage and fix it with the holders.
Select the 4x objective rotating the revolving nosepiece.
Center the observed specimen in the field of view.
Rotate the focusing knob to slowly raise the stage until the objective is close to the specimen;
keep checking the distance between the objective and the object to avoid their contact.
CAUTION: The objective should not touch the specimen, otherwise the objective or/and the
specimen might be damaged.
Look through the installed eyepiece and lower the stage slowly rotating the focusing knob until
you see the sharp image of the observed specimen.
Such adjustment protects the frontal lens from contacting the object when you use objectives
of other magnifications; though, slight refocusing might be required.
If the image is too bright, adjust the diaphragm disk until the passing light ray is reduced to a
comfortable brightness level. If the image is too dark, increase the light ray.
Selecting the objective
Start your observations with the lowest magnification objective (4x) and select a specimen
segment for detailed research. Then move the specimen to center the selected segment in the
field of view, to make sure it keeps centered when the objective is changed to a more powerful
one. Once the segment is selected, you should center its image in the microscope's field of view
as precisely as possible. Otherwise, the desired segment might fail to center in the field of view
of the higher power objective.
Now you can switch to a more powerful objective by rotating the revolving nosepiece. Adjust
the image focus, the iris diaphragm and the illumination brightness if required.
When using a 100x objective lens, you have to fill the space between the lens and the specimen
with immersion oil. There should be no air bubbles in the oil, as they might reduce the resulting
quality of the image. You must wipe the 100x objective clear after using it.
Похожие устройства
- Rutrike Атлант 2000 72V/2200W синий 021347-1970 Инструкция к Rutrike Атлант 2000 021347-1970
- Rutrike Бумеранг 022656-2338 Инструкция к Rutrike Атлант 2000 021347-1970
- Rutrike Бумеранг 022656-2339 Инструкция к Rutrike Атлант 2000 021347-1970
- Rutrike Бумеранг 022656-2342 Инструкция к Rutrike Атлант 2000 021347-1970
- Rutrike D1 1200 60V900W, синий 021492-1974 Инструкция к Rutrike Атлант 2000 021347-1970
- Rutrike Экипаж Люкс 022667-2372 Инструкция к Rutrike Атлант 2000 021347-1970
- Rutrike Экипаж Люкс 022667-2431 Инструкция к Rutrike Атлант 2000 021347-1970
- Rutrike Экипаж Люкс 022667-2433 Инструкция к Rutrike Атлант 2000 021347-1970
- Rutrike Караван 022926-2418 Инструкция к Rutrike Атлант 2000 021347-1970
- OMAN NOZYCOWE lux 70х110см, высота 300см УТ000000040 Инструкция к OMAN NOZYCOWE LUX УТ000000040
- OPET Fullgear FRM 75W-80 GL-4, 205 л 601216091 Инструкция к OPET Fullgear FRM 75W-80 601216091
- Универсал 602230 Инструкция
- OMAN NOZYCOWE lux 70х120см, высота 300см УТ000000042 Инструкция к OMAN NOZYCOWE LUX УТ000000042
- OMAN NOZYCOWE lux 70х80см, высота 300см УТ000000046 Инструкция к OMAN NOZYCOWE LUX УТ000000046
- OMAN NOZYCOWE Lux 70х90см, высота 300см УТ000000048 Инструкция к OMAN NOZYCOWE LUX УТ000000048
- MPF ИС.072219 Чертеж
- OMAN NOZYCOWE TERMO 60х120см, высота 285см УТ000026653 Инструкция к OMAN NOZYCOWE TERMO УТ000026653
- OMAN NOZYCOWE TERMO 60х70 см УТ000000050 Инструкция к OMAN NOZYCOWE LUX УТ000000033
- OMAN NOZYCOWE TERMO 70х100 см УТ000000051 Инструкция к OMAN NOZYCOWE LUX УТ000000033
- OMAN NOZYCOWE TERMO 70х120 см, h-290 см УТ000000052 Инструкция к OMAN NOZYCOWE TERMO УТ000000052