4 EN
ozone meter OZ-ONE
The impact of ozone on human beings
The sensitivity to ozone depends on its concentration and varies
for each individual. Ozone is an oxidative irritant gas, affecting
eyes, nose, pharynx and lungs even at low concentrations. The
mucous membranes are unable to stop it seeing as ozone is
hardly soluble in water. As a result, the gas can be carried
deeper into the lungs than other irritant gases. Concentrations
of 200µg/mm
3
and higher can cause the following symptoms:
• irritations of the mucous membranes, eyes and the
respiratory tract
• hoarseness, coughs and headaches
• feeling of constriction behind the sternum
• reduced physical performance
The main damage is caused in the respiratory tract which can
lead to breathing difficulties and a reduced respiratory volume.
Late complications can include nosebleeds, a bronchitis (or
tracheitis) or a pulmonary oedema. But the transition from
irritations without lasting consequences to long-term changes
with pathological significance is very smooth.
Ozone threshold and target values
The information threshold for ozone concentrations amounts to
180µg/m
3
(1-hour value) and the alert threshold is 240µg/m
3
(1-hour value). From an ozone concentration of 180µg/m
3
the
media starts to inform the public of the recommended
behaviour. Furthermore, a target value has been specified to
protect human health: Averaged over three years, the daily
maximum 8-hour value of 120µg/m
3
must not be exceeded on
more than 25days per calendar year. In the long run, the
maximum average values determined over an 8-hour period are
not supposed to exceed 120µg/m
3
altogether. To protect the
vegetation, a target value of 18,000µg/m
3
applies for a 5-year
average. This is the summed up difference between the hourly
average values above 80µg/m
3
measured during the daylight
hours (8a.m. to 8p.m.) in the main growing season between
May and July and 80µg/m
3
.
Device depiction
6 7 8 10 119
4
3
2
1
5
12
13
No. Designation
1 Measuring probe with protective cap
2 MAX/MIN button
3 UNIT button
4 Lamp button
5 MiniUSB port
6 Tripod thread
7 SET button
8 MODE button
9 Power button
10 HOLD button
11 Display
12 Battery compartment with cover
13 Connector for the power adapter
Похожие устройства
- Iek УКД D=37мм IP55 YUK10-37-55 Инструкция к товару
- Iek УКД D=40мм IP66 YUK10-40-66 Инструкция к товару
- Энкор 10314 Инструкция к товару
- Антиток УНП-10 БД до 10 кВ, 11 кг 315058 Инструкция
- Petzl i'd evac самоблокирующееся спусковое для высотных работ D020CA01 Инструкция
- Chint NJR2-45D 84А 45кВт 489026 Паспорт
- Chint NJR2-55D 103А 55кВт 489027 Паспорт
- Chint NJR2-7.5D 15А 7.5кВт 489019 Паспорт
- Доступная Автоматика 380в 11квт 22a modbus rtu DA40 22-A-3P3 Руководство
- Доступная Автоматика 380в 45квт 90a modbus rtu DA40 90-A-3P3 Руководство
- Innovert номинальный ток 110 а, питание управления 220в ac, rs-485 SSD553A43E Быстрый Пуск
- Innovert номинальный ток 110 а, питание управления 220в ac, rs-485 SSD553A43E Инструкция
- Innovert номинальный ток 12 а, питание управления 24в dc, rs-485 SSD222D21E Быстрый Пуск
- Innovert номинальный ток 12 а, питание управления 24в dc, rs-485 SSD222D21E Инструкция
- Innovert номинальный ток 15 а, питание управления 24в dc, rs-485 SSD752D43E Быстрый Пуск
- Innovert номинальный ток 15 а, питание управления 24в dc, rs-485 SSD752D43E Инструкция
- Innovert номинальный ток 22 а, питание управления 24в dc, rs-485 SSD113D43E Быстрый Пуск
- Innovert номинальный ток 22 а, питание управления 24в dc, rs-485 SSD113D43E Инструкция
- Innovert номинальный ток 30 а, питание управления 220в ac, rs-485 SSD153A43E Быстрый Пуск
- Innovert номинальный ток 30 а, питание управления 220в ac, rs-485 SSD153A43E Инструкция