FISCHER Анкер FHBIIA S 10x60/10A4 10 шт 97630 Инструкция к товару онлайн [7/46] 858640
![FISCHER Капсула FHB II-P 12x75 10 шт 96848 Инструкция к товару онлайн [7/46] 870374](/views2/2095893/page7/bg7.png)
Capsule FHB II - A L · FHB II - A S
When working with FHB II capsules, we recommend using the machine setting tool RA-SDS
(item no. 62420).
D I
Pre-positioned installation with capsule, FHB II - A S and FHB II - A L anchor rods
1. Drill the hole. It is not necessary to clean the hole.
2. Inserting the FHB II capsule. See table 3 for FHB II anchor rod and the corresponding FHB II capsule.
3. Installing anchor rods. Use a suitable hammer drilling machine (see table 3) and the included positioning
screw to rotate or hammer the anchor rod into place. Use our RA-SDS setting tool for this purpose. If the
setting depth is aligned with the concrete surface: STOP !
Once the setting depth has been reached, mortar must exit the drill hole until it makes contact with the
concrete surface. Visible inspection ! – If this is not the case, the FHB II anchor rod must be immediately
removed and reinstalled after a second FHB II capsule has been installed.
4. Hardening times. Observe the hardening times of the capsule mortar (table 2). Attaching the installation
wedges. Check that the installation is secure by applying the torque tinst specified in table 3.
D II
Push-through
installation
with capsule, only with FHB II - A S anchor rod
1. Drill the hole. It is not necessary to clean the hole.
2. Inserting the FHB II capsule. See table 3 for FHB II anchor rod and the corresponding FHB II capsule.
3. Installing anchor rods. Use a suitable hammer drilling machine (see table 3) and the included positioning
screw to rotate or hammer the anchor rod into place. Use our RA-SDS setting tool for this purpose. If the
setting depth is aligned with the concrete surface: STOP !
Once the setting depth has been reached, mortar must exit the drill hole until it makes contact with the
concrete surface. Visible inspection ! – If this is not the case, the FHB II anchor rod must be immediately
removed and reinstalled after a second FHB II capsule has been installed.
4. Hardening times. Observe the hardening times of the capsule mortar (see table 2). Attaching the instal-
lation wedges. Check that the installation is secure by applying torque T
inst
specified (table 3).
7
Table 2 Capsule hardening times
Storage temp.
ºC
Hardening time in minutes
FHB II-P FHB II-PF*
– 5 240 8
+ 0 45 6
+ 10 20 4
≥ + 20 10 2
* Max. capsule temperature: +30 °C.
IMPORTANT:
If the concrete is
wet and the drill
is filled with
water, the har-
den ing times
must be doubled !
h
ef
t
fix
h
o
T
d
o
inst
M
d
f
Table 3 Installation parameters for injection and capsule system:
Drill
hole
Ø
d
o
Drill-
ing
depth
h
o
Through
hole
Ø d
f
Anchor-
ing
depth
h
ef
Torque
T
inst
A/F
width
SW
BS brush
Injec-
tion
mortar
scale
divisions
Recom-
mended
hammer
drill
Capsule
correspond.
FHB II-P/
FHB II-PF
mortar
capsule
Dimensions [mm] [mm] [mm] [mm] [Nm] [–] Ø mm Art.-No.
[–] [kg]
FHB II - AL M 8 x 60 10 75 9 60 15 13 10 78178 3 2–3 8 x 60
FHB II - AL M10 x 95 12 110 12 95 20 17 12 78179 5 2–3 10 x 95
FHB II - AL M12 x 100 14 115 14 100 40 19 14 78180 6 2–3 12 x 100
FHB II - AL M12 x 120 14 135 14 120 40 19 14 78180 7 2–3 12 x 120
FHB II - AL M16 x 125 18 145 18 125 60 24 16/18 78181 9 2–3 16 x 125
FHB II - AL M16 x 145 18 165 18 145 60 24 16/18 78181 11 2–3 16 x 145
FHB II - AL M16 x 160 18 175 18 160 60 24 16/18 78181 13 4–5 16 x 160
FHB II - AL M20 x 210 25 235 22 210 100 30 25 97806 33 4–5 20 x 210
FHB II - AL M24 x 210 25 235 26 210 100 36 25 97806 33 4–5 24 x 210
FHB II - AS M10 x 60 10 75 12 60 15 17 10 78178 3 2–3 10 x 60
FHB II - AS M10 x 75 10 90 12 75 15 17 10 78178 4 2–3 10 x 75
FHB II - AS M12 x 75 12 90 14 75 30 19 12 78179 4 2–3 12 x 75
FHB II - AS M16 x 95 16 110 18 95 50 24 16/18 78181 8 4–5 16 x 95
FHB II - AS M20 x 170 25 190 22 170 100 30 25 97806 26 4–5 20 x 170
FHB II - AS M24 x 170 25 190 26 170 100 36 25 97806 26 4–5 24 x 170
MOAL FHB II_72x108_114104.indd 7 05.09.13 11:37
Похожие устройства
- FISCHER Анкер FHBIIA S12x75/25 A4 10 шт 97636 Инструкция к товару
- GNV Chain Cleaner GСС1151015589575500200 Инструкция к GNV Chain Cleaner GСС1151015589575500200
- SIKA sil-141 Aqua белый КРТ280 746750 Инструкция к товару
- SIKA sil-141 Aqua прозрачный КРТ280 746731 Инструкция к товару
- Церезит CM 17 класс C2TES1, 25 кг 792212 ТО
- Основит МАКСИПЛИКС AC161 E S1 класс C2TES1, 25 кг 93548 Инструкция к товару
- Основит Профи Мрамор МАКСИПЛИКС АС17 EW S1 класс C2TES1, 25 кг 87557 инструкция
- Litokol LITOSIL АНТРАЦИТ 280 504900001 техническое описание
- Litokol LITOSIL ШОКОЛАД 280 м 504890001 техническое описание
- KUDO быстросохнущая акриловая универсальная глянцевая RAL 9003 белая KU-A9003 Инструкция к товару
- KUDO быстросохнущая акриловая универсальная глянцевая RAL 1001 бежевая KU-A1001 Инструкция к товару
- KUDO быстросохнущая акриловая универсальная глянцевая RAL 9005 чёрная KU-A9005 Инструкция к товару
- KUDO быстросохнущая акриловая универсальная глянцевая RAL 4008 фиолетовая KU-A4008 Инструкция к товару
- KUDO быстросохнущая акриловая универсальная глянцевая RAL 5012 голубая KU-A5012 Инструкция к товару
- KUDO быстросохнущая акриловая универсальная глянцевая RAL 8017 коричневая KU-A8017 Инструкция к товару
- KUDO быстросохнущая акриловая универсальная глянцевая RAL 2004 оранжевая KU-A2004 Инструкция к товару
- KUDO быстросохнущая акриловая универсальная глянцевая RAL 3015 розовая KU-A3015 Инструкция к товару
- KUDO быстросохнущая акриловая универсальная глянцевая RAL 6018 салатовая KU-A6018 Инструкция к товару
- KUDO RAL 7040 серая высокоглянцевая объем 520 мл KU-A7040 Инструкция к товару
- KUDO быстросохнущая акриловая универсальная глянцевая RAL 5005 синяя KU-A5005 Инструкция к товару