Ada А00689 PDF-инструкция онлайн [2/2] 860387
![Ada А00689 PDF-инструкция онлайн [2/2] 860387](/views2/2097846/page2/bg2.png)
adainstruments.com
No.101 Xinming West Road, Jintan Development Zone,
Changzhou Jiangsu China
Made In China
OPERATING MANUAL
ZAC 1000 PLUS
Non-contact voltage detector
SPECIFICATIONS
Detection .................................................. AC voltage, 12...1000V (50/60 hz)
Operation temperature ........................ 0 ... +40°С
Operation humidity ............................. <90%RH
Storage temperature ............................ -10 ... +50°С
Power supply ........................................... 2 х ААА 1,5V batteries
Dimensions, mm .....................................174х34х23
Weight ...................................................... 60 gr
SAFETY INSTRUCTIONS
Before you start working with a non-contact voltage detector, read the safety instruc-
tions.
WARNING
• To avoid electric shock or harm to human body, please read this manual care-
fully before using this AC voltage tester, otherwise all protection functions will
be useless for the user.
• If the power indicator does not turn on, do not attempt to use this tool.
• Before operation, test the tool on a known voltage area to make sure it works
properly.
• If the tool detected AC voltage, and no LED or sound is heard, there is still a
possibility that AC/DC voltage is present.
• Do not use the tool, if it has been damaged or does not function properly. Be-
fore use, pay attention to the test pin, if it is broken or cracked, the tool is for-
bidden to use.
• Do not use the tool if the voltage exceeds 1000 V. To avoid electric shock, do
not use the tool if it is wet.
• If the detected AC voltage exceeds 30V, be careful. It is a possibility to get an
electric shock.
BATTERY REPLACEMENT
Press the latch on the battery cover and gently pull it up. Replace batteries. Observe
polarity.
OPERATION
1. Press button (4) to switch on the tool. A beep will sound and the display will
light up. To turn o the device, press the button (4) again. Two short beeps will
sound and the display will turn o.
2. Press button (5) to turn on the backlight. The LED (2) will light up. To turn o the
backlight, press the button (5) again. LED (2) will turn o.
3. Place the detector-sensor (1) of the device in or near the voltage zone. When
approaching a voltage source, an audible signal will sound. The closer the de-
tector-sensor (1) of the device to the source, the more often the sound signal
will sound. The display shows the scale LOW - HIS indicating the distance to the
voltage source. LOW - far, HIS - close. When the tool locates very close to the
voltage source, a frequent beep will sound, the scale will be completely lled,
the display will be highlighted in red. The red color of the display indicates the
presence of alternating voltage (12-1000V; 50/60 Hz). Green color indicates no
voltage. The device can be used to nd the location of live electrical wires in
walls, oors and ceilings.
4. If the signal is too weak, increase the sensitivity by pressing the button (6). A
beep will sound and the display will light yellow. To turn on the normal sensi-
tivity, press the button (6). A beep will sound and the display will turn green.
Note: The device cannot detect voltage in an armored cable or in a cable that
is in a metal case.
WARRANTY
This product is warranted by the manufacturer to the original purchaser to be free
from defects in material and workmanship under normal use for a period of two
(2) years from the date of purchase. During the warranty period, and upon proof of
purchase, the product will be repaired or replaced (with the same or similar model at
manufactures option), without charge for either parts of labour.
In case of a defect please contact the dealer where you originally purchased this prod-
uct. The warranty will not apply to this product if it has been misused, abused or
altered. Without limiting the foregoing, leakage of the battery, bending or dropping
the unit are presumed to be defects resulting from
misuse or abuse.
PRODUCT LIFE
Product life of the tool is 3 years. The battery and the tool should never be placed in
municipal waste.
EXCEPTIONS FROM RESPONSIBILITY
The user of this product is expected to follow the instructions given in operators’
manual. Although all instruments left our warehouse in perfect condition and adjust-
ment the user is expected to carry out periodic checks of the product’s accuracy and
general performance.
The manufacturer, or its representatives, assumes no responsibility of results of a
faulty or intentional usage or misuse including any direct, indirect, consequential
damage, and loss of prots. The manufacturer, or its representatives, assumes no
responsibility for consequential damage, and loss of prots by any disaster (earth-
quake, storm, ood ...), re, accident, or an act of a third party and/or a usage in other
than usual conditions. The manufacturer, or its representatives, assumes no respon-
sibility for any damage, and loss of prots due to a change of data, loss of data and
interruption of business etc., caused by using the product or an unusable product.
The manufacturer, or its representatives, assumes no responsibility for any damage,
and loss of prots caused by usage other thsn explained in the users’ manual. The
manufacturer, or its representatives, assumes no responsibility for damage caused
by wrong movement or action due to connecting with other products.
WARRANTY DOESN’T EXTEND TO FOLLOWING CASES:
1. If the standard or serial product number will be changed, erased, removed or wil
be unreadable.
2. Periodic maintenance, repair or changing parts as a result of their normal runout.
3. All adaptations and modications with the purpose of improvement and expansion
of normal sphere of product application, mentioned in the service instruction, with-
out tentative written agreement of the expert provider.
4. Service by anyone other than an authorized service center.
5. Damage to products or parts caused by misuse, including, without limitation, mis-
application or nrgligence of the terms of service instruction.
6. Power supply units, chargers, accessories, wearing parts.
7. Products, damaged from mishandling, faulty adjustment, maintenance with
low-quality and non-standard materials, presence of any liquids and foreign objects
inside the product.
8. Acts of God and/or actions of third persons.
9. In case of unwarranted repair till the end of warranty period because of damages
during the operation of the product, it’s transportation and storing, warranty doesn’t
resume.
WARRANTY CARD
Name and model of the product _____________________________________________________
Serial number ___________________ Date of sale________________________________________
Name of commercial organization ___________________________________________________
Stamp of commercial organization.
Warranty period for the instrument explotation is 24 months after the date of original
retail purchase. During this warranty period the owner of the product has the right for
free repair of his instrument in case of manufacturing defects. Warranty is valid only
with original warranty card, fully and clear lled (stamp or mark of thr seller is obliga-
tory). Technical examination of instruments for fault identication which is under the
warranty, is made only in the authorized service center.
In no event shall manufacturer be liable before the client for direct or consewuential
damages, loss of prot or any other damage which occur in the result of the instru-
ment outage. The product is received in the state of operability, without any visible
damages, in full completeness. It is tested in my presence. I have no complaints to
the product quality. I am familiar with the conditions of qarranty service and i agree.
Purchaser signature _________________________________
Before operating you should read service instruction!
If you have any questions about the warranty service and technical support contact seller
of this product
1
2
3
4
5
6
DESCRIPTION
The non-contact voltage detector ZAC 1000
PLUS is designed to detect voltage in sockets,
lighting xtures, switches, wires and cables,
as well as to determine the location of a wire
break.
FEATURES
1. Detector – sensor
2. Backlight LED
3. Display
4. Power On/O
5. Backlight On/O
6. Sensitivity adjustment
adainstruments.com
Похожие устройства
- Crown бесконтактный CT44092 Инструкция
- Квт КТ 89 PROLINE 88551 Инструкция к товару
- Iek ФР 601 сер. IP44 LFR20-601-2200-003 Руководство По Монтажу
- Iek ФР 602 сер. IP44 LFR20-602-4400-003 Руководство По Монтажу
- Сем AC-15 482285 Инструкция по эксплуатации
- Ada Wall Scanner 50 А00506 Инструкция по эксплуатации
- Makita LXT DLM532Z Инструкция по эксплуатации
- WORTEX MD 3009 MD3009000019 Инструкция к товару
- Квт 86214 Инструкция по эксплуатации
- МЕГЕОН 45400 к0000032658 Руководство пользователя
- Yato YT-73131 Инструкция по эксплуатации
- Metabo RM 36-18 LTX BL 36 без аккумулятора и зарядного устройства 601716850 T0525 Расширенное описание
- Metabo RM 36-18 LTX BL 36 без аккумулятора и зарядного устройства 601716850 T0525 Инструкция
- Даджет KIT MT8056 4 266 Инструкция к товару
- МЕГЕОН 08082 Инструкция к товару
- Axiom A9651 Лист технической информации
- МЕГЕОН 08013 к0000034425 Инструкция по эксплуатации
- МЕГЕОН 08088 00000006476 Инструкция
- МЕГЕОН 08015 к0000034427 Инструкция по эксплуатации
- МЕГЕОН 08003 к0000026360 Инструкция по эксплуатации