G DAILY USE
FOREWORD
The only operations that need to be done for daily use are partial and/or resettable
total register resetting. The user should use only the dispensing system of K900. Oc-
casionally the meter may need to be configured or calibrated. To do so, please refer to
the relevant chapters.
Below are the two typical normal operation displays. One display page shows the partial and reset total
registers. The other shows the partial and general total. Switchover from resettable total to general total
display is automatic and tied to phases and times that are in factory set and cannot be changed.
*
The Partial register positioned in the top part of the display indicates the
quantity dispensed since the RESET key was last pressed
*
The RESET Total register, positioned in the lower part of the display, indicates
the quantity dispensed since the last RESET Total resetting. The RESET Total
cannot be reset until the Partial has been reset, while vice versa, the Partial can
always be reset without resetting the RESET Total. The unit of measurement of
the two Totals can be the same as the Partial or else different according to the
factory or user settings.
*
The General TOTAL register (Total) can never be reset by the user. It continues
to rise for the entire operating life of the meter.
*
The register of the two totals (Reset Total and Total) share the same area and
digits of the display. For this reason, the two totals will never be visible at the
same time, but will always be displayed alternately.
*
The General Total (Total ) is shown during Meter standby
*
The Reset Total is shown:
- At the end of a Partial reset for a certain time (a few seconds)
- During the entire dispensing stage
- For a few seconds after the end of dispensing. Once this short time has
expired. Meter switches to standby and lower register display switches to
General Total
NOTE
6 digits are available for Totals, plus two icons x 10 / x100. The increment
sequence is the following:
0.0 -> 99999.9 -> 999999 -> 100000 x 10 -> 999999 x 10 ->100000 x 100 ->
999999 x 100
Похожие устройства
- Piusi K900 METER 3in BSP F0049900B Инструкция
- Ryobi RB18L90 5133002865 Таблица времени работы инструментов ONE+ с аккумуляторами разной емкости
- ТАУ СЧЕТ-1М 00000002083 Инструкция по эксплуатации
- ТАУ СЧЕТ-1М 00000002083 Свидетельсво об утверждении типа
- ТАУ СЧЕТ-2 00-00000047 Инструкция по эксплуатации
- ТАУ СЧЕТ-2 00-00000047 Свидетельство об утверждении типа
- ТАУ СЧЕТ-2 00-00000047 Методика поверки секундомера СЧЕТ-2
- CNIC Шан 115-320 20-170 0.01, для внутренних канавок, Н-40 мм, нержавеющая сталь 31463 Инструкция к CNIC Шан 115-320 20-170 0.01 31463
- CNIC Шан 115-325 25-225 0.01, для внутренних канавок, Н-50 мм, нержавеющая сталь 31464 Инструкция к CNIC Шан 115-325 25-225 0.01 31464
- CNIC Шан 116-320 0-150, 0.01, для наружных канавок, H-40 мм 35181 Инструкция к CNIC Шан 116-320 0-150, 0.01 35181
- Kinex (K-MET) ШЦЦ-1 150мм, 0.01мм, DIN862 ABSOLUTE ZERO 6040-05-150 Письмо
- RGK SC-150 779487 Руководство по эксплуатации Штангенциркуль электронный SC-150
- RGK SC-200 779494 Руководство по эксплуатации Штангенциркуль электронный SC-150
- RGK SC-300 779500 Руководство по эксплуатации Штангенциркуль электронный SC-150
- ORAS Optima Bluetooth 1714FZ 00000083716 Инструкция к товару
- AM.PM F50A02400 инструкция
- EKF Минск ОП 10А без заземления, белая, Basic EGR10-102-10 Паспорт
- Deko DKIT04 с шаровым механизмом, меню на русском языке 065-0957 Инструкция по эксплуатации
- Deko DKIT05 c широким дисплеем 065-0346 Инструкция по эксплуатации
- Verto 15G751 15G751