Fiberglass reinforced plastic tank is the cylinder shaped plastic vessel with the lter
media. Control valve is mounted on the threaded top opening. Riser pipe runs down to
the bottom of the tank inside the pressure vessel, transporting water out of the lter during
service and into the lter during backwash. Bottom distributor is attached to its end to spread
ow of water uniformly and screen against ne particles.
Brine regenerable systems (FU and FK) include a brine tank – a plastic container with salt
pellets where the brine is stored then drawn from during regeneration.
Control valve.
CE, CI, and CT type control valves use a plunger piston mechanism to route inuent water
accordingly to the current cycle of operation. DV valves use a rotary disk mechanism.
CE, CI and DV control valves for softening systems (FU and FK series) have 5 cycles;
non-brine regenerable lters have 3 cycle CT control valves. The cycles are as follows:
1. in service mode, inlet water is sent through the lter bed to the puried water outlet;
2. during backwash, the control valve sends inlet water across the lter bed in the upow
direction to u it up and release trapped impurities to drain outlet;
3. during fast rinse, inlet water is sent through lter bed downow and then to drain outlet;
4. (CE, CI, and DV only) during brine regeneration, inlet water is sent through brine injection
system to suction brine from brine tank and slowly displace it across lter bed to drain outlet;
5. (CE, CI, and DV only) during brine tank rell, inlet water is sent through the lter bed,
softened euent rells the brine tank.
Control valve
type
Operating
cycles
Meter and
brine system
Special
connectivity
Special
rmware
functionality
CE;
Twin
5 Yes • 2 motorized valves
• dP switch
• NO/NC 12 VDC wet contact
• Twin interconnect
• 63 day history/diagnostics
• 4 display languages
• Selectable physical units
CI 5 Yes • 1 motorized valve
• dP switch
• Twin interconnect
• 63 day history/diagnostics
CT 3 — • dP switch
DV 5 Yes — • 63 day history/diagnostics
For more information about your control valve, please refer to control valve manual.
Похожие устройства
- Ecosoft FK1252CIMIXP Инструкция к Ecosoft FU1354CE
- Барьер «COMPACT OSMO 100» быстросъемный Н262Р01 Руководство пользователя
- Барьер «COMPACT OSMO 100М» быстросъемный Н262Р02 Руководство пользователя
- Барьер профи осмо 100 м (исп. лайт) с минерализатором Н152Р06 Руководство пользователя
- AM.PM Inspire 2.0 180х80 A0 W52A-180-080W-A инструкция
- Барьер Профи Осмо 600 Н151Р17 руководство пользователя
- Ecosoft Absolute 5-50P с помпой на станине MO550PSECOEXP Инструкция
- Ecosoft ABSOLUTE с помпой на станине MO550PSECO Инструкция
- Ecosoft ROBUST1000, ROBUSTЕСО Инструкция к Ecosoft ROBUST1000
- Ecosoft ROBUST 1500 Инструкция к Ecosoft ROBUST1000
- Ecosoft Robust1500 с E-connect ROBUST1500EC Инструкция к Ecosoft ROBUST1000
- Ecosoft Robust1500 с E-connect ROBUST1500EC Инструкция к Ecosoft Robust1500 с E-connect ROBUST1500EC
- Ecosoft ROBUST3000 150л/ч Инструкция к Ecosoft ROBUST1000
- Ecosoft ROBUST3000 с E-connect Инструкция к Ecosoft ROBUST1000
- Ecosoft ROBUST3000 с E-connect Инструкция к Ecosoft Robust1500 с E-connect ROBUST1500EC
- Ecosoft ROBUSTPro E-connect 60л/ч, ROBUSTPROCEC Инструкция к Ecosoft ROBUST1000
- Ecosoft Sense MO675MPECOSENSE Строение фильтра
- AM.PM Like, A0 170х70 см W80A-170-070W-A инструкция
- Ecosoft цвет Espresso ROBUSTPROB Инструкция к Ecosoft ROBUST1000
- Гейзер Аллегро ПМ с баком 12л., кран №7 20039 Инструкция к Гейзер Аллегро ПМ 20039