If the washing provides no desirable result, the filtering element should be cleaned or
replaced (if heavily contaminated). Before cleaning or replacement of the filtering element,
the system inlet shutoff tap should be closed. Further, washing valve should be opened with
draining the pipeline section containing the filter. To clean the filtering element itself, unscrew
the bowl, remove the filtering element, clean or replace it.
ATTENTION: to clean the filter element, do not use solvents or detergents, including the
acidiferous detergents. Further, insert the filtering element to the casing and screw the bowl
on. Close the washing valve, then open the shutoff taps, open the closest water tap and drain
the initial flowing out water. Check the filter for leak tightness.
ATTENTION: do not connect the washing valve to the sewage network without the jet break,
since blockage or overflow of the sewage network may result in the effluent water getting into
the water supply pipeline.
According to the requirements of DIN 1988-, part 8, the leak tightness and filter pollution level
should be visually checked once per 2 months with washing the filter. The filter element is
recommended to be replaced at least once per 6 months, quick-wearing sealing parts should
be replaced once in 3 years.
The product described in this technical passport, is a technically sophisticated device, which
must be installed by a person having the appropriate qualifications and experience with the
equipment.
Installation and commissioning must be carried out by an authorized and certified company.
Profactor Armaturen GmbH company reserves the right to make construction changes that
do not affect the technical characteristics of the device, as well as its functional features.