Timberk AC TIM 48LC DT5-K Инструкция к Timberk AC TIM 24LC DT5-K онлайн [5/32] 872749
![Timberk AC TIM 48LC DT5-K Инструкция к Timberk AC TIM 24LC DT5-K онлайн [5/32] 872749](/views2/2111579/page5/bg5.png)
www.timberk.com • Electric air conditioner
5
Model
AC TIM 18LC DT3 AC TIM 24LC DT3 AC TIM 36LC DT3 AC TIM 48LC DT3 AC TIM 60LC DT3
Indoor unit
AC TIM 18LC DT3 AC TIM 24LC DT3 AC TIM 36LC DT3 AC TIM 48LC DT3 AC TIM 60LC DT3
Outdoor unit
AC TIM 18LC DT3-01 AC TIM 24LC DT3-01 AC TIM 36LC DT3-01 AC TIM 486LC DT3-01 AC TIM 60LC DT3-01
Operating temperature range: cooling, ° C
+15~+49 +15~+49 +15~+49 +15~+49 +15~+49
Operating temperature range: heating, ° C
-15~+24 -15~+24 -15~+24 -15~+24 -15~+24
Net weight, indoor unit (kg)
34,0 36,0 36,0 52,0 52,0
Net weight, outdoor unit (kg)
38,0 50,0 71,0 101,0 102,0
Gross weight, indoor unit (kg
40,0 42,0 42,0 59,0 59,0
Gross weight, outdoor unit (kg)
41,0 54,0 81,0 112,0 113,0
Net dimensions, indoor unit (mm)
890x785x290 890x785x290 890x785x290 1250x785x290 1250x785x290
Net dimensions, outdoor unit (mm)
800x286x530 822x302x655 903x354x857 940x368x1366 940x368x1366
Packing dimensions, indoor unit (mm)
1100x870x360 1100x870x360 1100x870x360 1460x870x360 1460x870x360
Packing dimensions, outdoor unit (mm)
920x400x620 945x430x725 1030x410x980 1080x460x1500 1080x460x1500
Похожие устройства
- General Climate (11.20) 50 Па GDU-W-12DR3 2T Инструкция
- General Climate (12.30) 30/60 Па GDU-F-14DR 4T Инструкция
- General Climate (12.30) 30/60 Па GDU-F-14DR 4T Характеристики вентиляторов фанкойлов
- General Climate (13.00) 50 Па GDU-W-14DR3 2T Инструкция
- General Climate (14.00) 30/60 Па GDU-W-16TR 2T Инструкция
- General Climate (2.70) 30/60 Па GDU-F-03DR 4T Инструкция
- General Climate (3.60) 30/60 Па GDU-F-04DR 4T Инструкция
- General Climate (4.41) 50 Па GDU-W-04DR3 2T Инструкция
- General Climate (4.50) 30/60 Па GDU-F-05DR 4T Инструкция
- General Climate (5.00) 50 Па GDU-W-05DR3 2T Инструкция
- General Climate (5.50) 30/60 Па GDU-F-06DR 4T Инструкция
- МЕГЕОН 11005 00000003192 Инструкция к товару
- General Climate (7.50) 30/60 Па GDU-F-08DR 4T Инструкция
- General Climate (8.03) 50 Па GDU-W-08DR3 2T Инструкция
- General Climate (9.00) 30/60 Па GDU-F-10DR 4T Инструкция
- General Climate (9.27) 50 Па GDU-W-10DR3 2T Инструкция
- Тепломаш КЭВ-3,5Ф30КН2 234019 Паспорт фанкойлов Тепломаш
- Тепломаш КЭВ-5Ф30КН2 234042 Паспорт фанкойлов Тепломаш
- Тепломаш КЭВ-7Ф30КН2 234023 Паспорт фанкойлов Тепломаш
- Timberk CW1 TIM 1000 DT2 Инструкция к товару