8. Operating trouble
ATTENTION! Before any intervention dis-
connect the pump!
9. Spare parts
Spares should be ordered through local trade
outlets.
To avoid queries and incorrect orders, all the
data on the name plate must be indicated when
ordering.
10. Disposal
Information on the collection of used electrical
and electronic products
Proper disposal and appropriate recycling of this
product prevents damage to the environment
and dangers to your personal health.
NOTICE: Disposal in domestic waste is forbid-
den !
In the European Union, this symbol can appear
on the product, the packaging or the accompa-
nying documentation. It means that the electrical
and electronic products in question must not be
disposed of along with domestic waste.
To ensure proper handling, recycling and disposal
of the used products in question, please note the
following points:
• Only hand over these products at designated,
certied collecting points.
• Observe the locally applicable regulations!
Please consult your local municipality, the near-
est waste disposal site, or the dealer who sold
the product to you for information on proper
disposal. For further information on recycling, go
to www.wilo-recycling.com.
Subject to technical alterations!
Faults Causes Remedies
The fails to start No current Check the line. Replace the fuses if
necessary. Close the overload release or
the switch of the control box
Winding or cable open-circuit Check the resistances between the cable
ends; if necessary replace the cable
(Caution: in case of replacing, reconnect
correctly the supply wires according to
the colours)
Rotor stalled (the motor ”growls”) Allow to cool downDismantle the impel-
ler and clean it
The pump fails to deliver or deliers too
little
Discharge pipe obstructed Remove the pipe and clean it
Impeller obstructed by particles (See 8.1 - c)
The check valve is mounted
upside down
Check it
The pump trips out Faulty electrical installation Check the whole electrical installation
Pump stalled (See 8.1 - c)
The pump is hard to turn (See 8.1 - c)
Installation and operating instructions - Wilo-Initial DRAIN
Похожие устройства
- Braun CG7040 Руководство по эксплуатации
- Vard VSK4 Руководство по эксплуатации
- Vard VSK1 Руководство по эксплуатации
- Vard VSK2 Руководство по эксплуатации
- Vard VSK3 Руководство по эксплуатации
- Kitfort КТ-3676 Руководство по эксплуатации
- Thermex IRP 300 F Руководство по эксплуатации
- Hisense DH7S107BW Руководство по эксплуатации
- Kitfort КТ-2897 Руководство по эксплуатации
- Samsung Galaxy Tab A9 (SM-X115) 4/64GB LTE Темно-синий Руководство по эксплуатации
- Elikor ECO 60 XS нержавеющая сталь Руководство по эксплуатации
- Kitfort КТ-3511 Руководство по эксплуатации
- Samsung Galaxy Tab A9 (SM-X115) 8/128GB LTE Темно-серый Руководство по эксплуатации
- Kitfort КТ-3512 Руководство по эксплуатации
- Samsung Galaxy Tab A9 (SM-X115) 8/128GB LTE Темно-синий Руководство по эксплуатации
- Kitfort КТ-3513 Руководство по эксплуатации
- Dyson V15 Detect Submarine Gray Руководство по эксплуатации
- Denon AVR-S670H Руководство по эксплуатации
- Ballu BEC/PL-2000 Руководство по эксплуатации
- Ballu BEC/PL-500 Руководство по эксплуатации