ELECTRIC IMPACT DRILL
EN
Do not allow the machine work when there is extraneous or uncharacteristic noise in the engine or gear. When
there are noises turn o the tool and contact an authorized service.
Do not operate the machine when visible ashes appear in the engine ventilation openings, stop working and contact
the service center for diagnostics and, possibly, replacement of carbon brushes.
NOISE AND VIBRATION
Noise and vibration characteristics are given in the table №1.
However, if the Impact Drill will be used for other work with the use of working tools, not provided by the manu-
facturer, or maintenance will not meet the requirements, then the vibration level may be dierent.
ATTENTION!
Always use personal ear protection.
MAINTENANCE
ATTENTION!
Before starting maintenance and adjustment of the Impact Drill unplug the power cord from
the power outlet. To ensure quality and safe functioning keep your tool and vents clean at all
times.
•
If you notice a decrease in the frequency of rotation of equipment or extraneous noise during operation, it is neces-
sary to hand over the device to the service center for its diagnosis and repair.
•
Working tool maintenance. The use of the worn working tool reduces the eectiveness of the work and may
result in motor or gearbox failure, it is therefore necessary to periodically replace worn out tooling as soon
as this becomes necessary.
•
Electric motor care. You must be especially careful with the electric motor, avoid getting liquids and foreign
objects inside the case. Keep your ventilation holes clean, blow them regularly with compressed air or clean
them with a brush. When noticeable sparks appear, contact an authorized service center for diagnostics and possibly
replacement of carbon brushes.
To prevent dust and grease leakage this machine has a hermetic design. Therefore, the tool can be used for a long
time and you have no need to replace or add grease. After initial commissioning change lubrication every 6
months of operation. To replace the lubricant, contact the service center.
In case of any damage to the power cord turn o the Impact Drill immediately, carefully, without touching the places
of damage, disconnect it from the mains.
ATTENTION!
The tool uses power cord with mounting type Y: for security it must be replaced by authorized
repair shop personnel.
Possible faults
Fault Probable cause Problem solution
The tool does not turn on.
Broken power cord or mounting
wire, power cord malfunction.
Call the service center.
Faulty switch. Call the service center.
Brush wear. Call the service center.
Circular re on the collector.
Fault in the armature winding. Call the service center.
Wearout /”hang ” of brushes. Call the service center.
Похожие устройства
- SLS Zigbee SWC-03 Руководство по эксплуатации
- ТриЯ Нуар Руководство по эксплуатации
- SLS WiFi SWC-04 Руководство по эксплуатации
- EXITEQ EXO-109 Руководство по эксплуатации
- ТриЯ Тип 1 Руководство по эксплуатации
- ТриЯ Тип 1 Руководство по эксплуатации
- Tefal Morning Fair Grey KO2M0B10 серый Руководство по эксплуатации
- Krups Virtuoso+ XP444C10 Руководство по эксплуатации
- SLS WiFi SWC-05 Руководство по эксплуатации
- Nebula Cosmos Max Руководство по эксплуатации
- Kitfort КТ-1046 Руководство по эксплуатации
- Matrix нейлер пневматический 3 в 1, 16/18GA (57427) Руководство по эксплуатации
- Patriot MP 4090 S Руководство по эксплуатации
- Kitfort КТ-6192 Руководство по эксплуатации
- Denzel DWP-1500 (94205) Руководство по эксплуатации
- ТриЯ 104592 Руководство по эксплуатации
- ТриЯ Марли Руководство по эксплуатации
- ТриЯ Diamond Тип 1 Руководство по эксплуатации
- Patriot Сибирь 85 ЕТ Руководство по эксплуатации
- ТриЯ Тип 14 Руководство по эксплуатации