Buffalo LS-X2.0TL-EU Инструкция по эксплуатации онлайн [203/211] 106598

Buffalo LS-X2.0TL-EU Инструкция по эксплуатации онлайн [203/211] 106598
LinkStation User Manual 202
Appendix
E14 The RAID array cannot be mounted. Run the RAID array disk check in the
LinkStation's settings.
E15 The bad sectors in the hard drive have reached a dangerous level. Replace the hard
drive indicated by the red Status LED.
E16 Unable to nd the hard drive. Hard drive may be disconnected or may have failed.
After shutting down, reinstall the hard drive.
E22 Mounting of the hard drive failed. Format the hard drive. After formatting, if the error
still appears after rebooting, replace the hard drive. If the error is displayed again,
contact Bualo technical support for assistance.
E23 An error occurred, so the hard drive was removed from the RAID array. Replace the
hard drive indicated by the red Status LED.
E30 The hard drive may be damaged. Replace the hard drive indicated by the red Status
LED.

Содержание

Похожие устройства

Скачать