Sea-Doo GTX Limited iS 2009 Инструкция по эксплуатации онлайн [203/555] 12053

Sea-Doo GTX Limited iS 2009 Инструкция по эксплуатации онлайн [203/555] 12053
Section 03 ELECTRONIC MANAGEMENT SYSTEMS
Subsection 03 (COMMUNICATION TOOLS AND B.U.D.S. SOFTWARE)
CAN LIGHT
STATUS WHAT TO DO
Light is
OFF
Check connection between MPI-2 and
diagnostic connector of vehicle.
Light is
RED
Check CAN wire
s/connectors on vehicle.
Light is
GREEN
Connections are GOOD. Communication
can take place on CAN side.
Communication Problems with
B.U.D.S.
Missing Module
If an “X” is shown in the status bar, it means that
no "ECU" is communicating with the MPI.
mmr2009-020-001
Check the following:
MPI protocol in B.U.D.S.
Connections between the PC computer and the
vehicle.
If one or more “ECU” is (are) not communicating
with the MPI a module may not be powered or is
defective.
Check to find which module is missing in B.U.D.S.
The tab of the missing module will not be visible
at the bottom of B.U.D.S. screen.
smr2009-028-001_a
1. iS tab not visible meaning this "ECU" is not communicating
If a mo
dule is missing, check wiring and power
suppl
y to that module.
Message Box: "No Vehicle Detected..."
If the following message box is displayed in
B.U.D.S.:
smr2008-020-003
1. Ensure both USB and CAN lights of MPI-2 are
GREEN. Refer to
MPI-2 CONNECTION TROU-
BLESHOOTING
subsection.
2. Check MPI-2 protocol. It must be set to
Kw2000 (500K).
rmr2008-020-003_en
Ensure the status bar shows the Kw2000 500K
and the number 4 to its right. Otherwise, refer
to
MPI-2 CONNECTION TROUBLESHOOTING
in
this subsection.
rmr2008-058-100
CONNECTION SUCCESSFUL
Number 4 means that 4 “ECUs” are connected:
–ECM
Information center
–iBR
–iS.
180 smr2009-028