Sea-Doo GTX Limited iS 2009 Инструкция по эксплуатации онлайн [234/555] 12053

Sea-Doo GTX Limited iS 2009 Инструкция по эксплуатации онлайн [234/555] 12053
Section 03 ELECTRONIC MANAGEMENT SYSTEMS
Subsection 04 (MONITORING SYSTEM AND FAULT CODES)
FAULT
CODE
MODULE DESCRIPTION POSSIBLE CAUSE SERVICE ACTION
U16A1
ECM
Cluster CAN Time out
error-Missin
g CAN ID
514h
Cluster fault d
etected by
ECM CAN circuit failure,
Instrument cluster or
ECM failure
Check CAN circu
its wires.
Replace instrument Cluster.
Refer to the Service Manual for
more details.
U16A2
ECM
Cluster CAN Time out
error-Missing CAN ID
230h
Cluster fault detected by
ECM CAN circui
t failure,
Instrument cluster or
ECM failure
Check CAN circuits wires.
Replace instr
ument Cluster.
Refer to the Service Manual for
more details.
U16A3
ECM
Cluster CAN T
ime out
error-Missing CAN ID
408h
Cluster fault detected by
ECM CAN circuit failure,
Instrument c
luster or
ECM failure
Check CAN circuits wires.
Replace instrument Cluster.
Refer to the S
ervice Manual for
more details.
U16A4
ECM
iBR CAN Time out
error-Miss
ing CAN ID
010h
iBR fault detected by
ECM CAN circuit failure,
iBR or ECM failure
Check CAN cir
cuits wires.
Replace iBR.
Refer to the Service Manual for
more detail
s.
U16A5
ECM
iBR CAN Timeout
error-Missing CAN ID
012h
iBR fault detected by
ECM CAN circuit failure,
iBR or ECM failure
Check CAN circuits wires.
Replace ins
trument iBR.
Refer to the Service Manual for
more details.
U16A6
ECM
Cluster check sum
error - CAN
ID230h
Cluster fault detected by
ECM CAN circuit failure,
Instrumen
tclusteror
ECM failure
Check CAN circuits wires.
Replace instrument Cluster.
Refer to th
e Service Manual for
more details.
U16A7
ECM
Cluster check sum
error - CAN ID408h
Cluster fa
ult detected by
ECM CAN circuit failure,
Instrument cluster or
ECM failur
e
Check CAN c
ircuits wires.
Replace instrument Cluster.
Refer to the Service Manual for
more detai
ls.
U16A8
ECM
iBR check sum error -
CAN ID010h
iBR fault detected by
ECM CAN circuit failure,
ECM software failure
Check CAN circuits wires.
Replace i
BR.
Refer to the Service Manual for
more details.
U16A9
ECM
iBR check sum error -
CAN ID012h
iBR fault detected by
ECM CAN circuit failure,
ECM software failure
Check CAN circuits wires.
Replace iBR.
Refer to t
he Service Manual for
more details.
smr2009-029 211