Asus rs720-x7-rs8 Инструкция по эксплуатации онлайн
Содержание
- First edition april 2012 2
- Chapter 1 product introduction 3
- Chapter 2 hardware setup 3
- Contents 3
- Chapter 3 installation options 4
- Chapter 4 motherboard info 4
- Chapter 5 bios setup 4
- Contents 4
- Chapter6 raidconfiguration 5
- Contents 5
- Chapter 7 driver installation 6
- Contents 6
- Canadian department of communications statement 7
- Federal communications commission statement 7
- Notices 7
- Reach information 7
- Class 1 laser product 8
- Electrical safety 8
- Operation safety 8
- Safety information 8
- About this guide 9
- Audience 9
- Contents 9
- Conventions 10
- References 10
- Typography 10
- Chapter 1 11
- Product introduction 11
- Before requesting support from the asus technical support team you must take note of the product s serial number containing 14 characters such as xxs0xxxxxxxxxx see the figure below 12
- Check your system package for the following items 12
- Rs720 x7 rs8 12
- Serial number label 12
- System package contents 12
- With the correct serial number of the product asus technical support team members can then offer a quicker and satisfying solution to your problems 12
- Xxs0xxxxxxxxxx 12
- Lga2011 xeon 13
- Plus other latest technologies through the chipsets onboard 13
- Series processors with em64t technology 13
- Systemspecifications 13
- The asus rs720 x7 rs8 feature the asus z9pr d12 4l server board the server supports intel 13
- Asus rs720 x7 rs8 1 5 15
- Front panel features 15
- Refer to section 1 front panel leds for the led descriptions 15
- The barebone server displays a simple yet stylish front panel with easily accessible features the power and reset buttons led indicators optical drive and two usb ports are located on the front panel 15
- Rear panel features 16
- The rear panel includes the expansion slots system power socket and rear fans the middle part includes the i o shield with openings for the rear panel connectors on the motherboard 16
- Internal features 17
- Front panel leds 18
- Lan rj 45 leds 18
- Led information 18
- Hdd status led 19
- Chapter 2 21
- Hardware setup 21
- Chassis cover 22
- Removing the rear cover 22
- Central processing unit cpu 23
- E5 2600 series processor family 23
- Installing the cpu 23
- Locate the cpu socket on the motherboard 23
- The motherboard comes with two surface mount lga 2011 socket r designed for the inte 23
- To install a cpu 23
- Apply some thermal interface material to the exposed area of the cpu that the heatsink will be in contact with ensuring that it is spread in an even thin layer 27
- Installing the cpu heatsink 28
- Gb 16gb and 32gb lr dimms into the dimm sockets using the memory configurations in this section 29
- Memoryconfigurations 29
- Overview 29
- System memory 29
- The figure illustrates the location of the ddr3 dimm sockets 29
- The motherboard comes with eight for cpu1 and four for cpu2 double data rate 3 ddr3 dual inline memory modules dimm sockets 29
- You may install 1gb 2gb 4gb 8gb 16gb and 32gb rdimms or 29
- Installing a dimm 31
- Removing a dimm from a single clip dimm socket 31
- Hard disk drives 32
- Expansion slots 34
- Installing an expansion card 34
- After installing the expansion card configure the it by adjusting the software settings 35
- Assign an irq to the card refer to the following tables 35
- Configuringanexpansioncard 35
- Install the software drivers for the expansion card 35
- Standard interrupt assignments 35
- Turn on the system and change the necessary bios settings if any see chapter 5 for information on bios setup 35
- Pci express x16 slot x16 link 36
- Pci express x8 slot x8 link 36
- The onboard pcie 1 3 and 4 slots provide one x8 gen3 link to cpu1 the onboard pcie 5 6 and 7 slots provide one x8 gen3 link to cpu2 these slots support vga cards and various server class high performance add on cards 36
- The onboard pcie 2 slot provides one x16 gen3 link to cpu1 and auto switches to x8 link if pcie3 is occupied this slot supports vga cards and various server class high performance add on cards 36
- Cable connections 37
- Standard cables connected to the motherboard 37
- Chapter 2 hardware setup 2 18 38
- Rs720 e7 rs12 38
- Sata sas backplane cabling 38
- Removable optional components 39
- System fans 39
- Redundant power supply module 40
- Installing asus pike raid card optional 41
- Chapter 3 43
- Installation options 43
- Attachingthefixinglatchestotheserver 44
- Installing friction rail kit items 44
- Mounting the server to the rack 47
- Chapter 4 49
- Motherboard info 49
- Layout contents 50
- Motherboard layout 50
- Jumpers 52
- Internal connectors 56
- Cpu front and rear fan connectors 4 pin cpu_fan1 2 frnt_fan1 4 rear_fan1 2 59
- The fan connectors support cooling fans connect the fan cables to the fan connectors on the motherboard ensuring that the black wire of each cable matches the ground pin of the connector 59
- This connector supports the vga high dynamic range interface 59
- Vga connector 10 1 pin vga_hdr1 59
- Lan led connector lan34_led1 60
- This led connector supports lan3 and lan4 leds this led connector supports lan3 and lan4 leds 60
- Serial general purpose input output connectors 8 1 pin psgpio1 2 isgpio1 sgpio1 61
- The sgpio 1 connectors are used for the intel rapid storage technology enterprise sgpio interface that controls the led pattern generation device information and general purpose data 61
- 24 pin eatxpwr1 8 pin eatx12v1 eatx12v2 63
- Eatx power connectors 63
- These connectors are for the eatx power supply plugs the power supply plugs are designed to fit these connectors in only one orientation find the proper orientation and push down firmly until the connectors completely fit 63
- Internal leds 67
- Bios setup 71
- Chapter 5 71
- Asus crashfree bios 3 utility 72
- Managing and updating your bios 72
- Recoveringthebiosfromausbflashdrive 72
- Asus ez flash utility 73
- Bupdater utility 74
- Updatingthebiosfile 74
- Asus rs720 x7 rs8 5 5 75
- Do not shut down or reset the system while updating the bios to prevent system boot failure 75
- The bios update is finished please restart your system 75
- The utility returns to the dos prompt after the bios update process is completed reboot the system from the hard disk drive 75
- The utility verifies the file then starts updating the bios file 75
- Bios setup program 76
- Advanced for changing the advanced system settings 77
- Asus rs720 x7 rs8 5 7 77
- Bios menu screen 77
- Boot for changing the system boot configuration 77
- Event logs for changing the event log settings 77
- Exit for selecting the exit options 77
- Main for changing the basic system configuration 77
- Menu bar 77
- Monitor for displaying the system temperature power status and changing the fan settings 77
- Security for changing the security settings 77
- Server mgmt for changing the server mgmt settings 77
- The menu bar on top of the screen has the following main items 77
- To select an item on the menu bar press the right or left arrow key on the keyboard until the desired item is highlighted 77
- Tool for configuring options for special functions 77
- Configurationfields 78
- General help 78
- Menu items 78
- Navigation keys 78
- Pop up window 78
- Scroll bar 78
- Submenu items 78
- Allows you to set the system date 79
- Allows you to set the system time 79
- Asus rs720 x7 rs8 5 9 79
- Main menu 79
- System date day xx xx xxxx 79
- System time xx xx xx 79
- When you enter the bios setup program the main menu screen appears the main menu provides you an overview of the basic system information and allows you to set the system date time settings 79
- 10 chapter 5 bios setup 80
- Advanced menu 80
- Be cautious when changing the settings of the advanced menu items incorrect field values can cause the system to malfunction 80
- Cpuconfiguration 80
- The advanced menu items allow you to change the settings for the cpu and other system devices 80
- Active processor cores all 81
- Allows you to enable or disable the intel hyper threading technology function when disabled only one thread per activated core is enabled configuration options disabled enabled 81
- Asus rs720 x7 rs8 5 11 81
- Configuration code numbers vary with cpu models 81
- Configuration options all 1 2 4 6 81
- Enter to view socket cpu information 81
- Execute disable bit enabled 81
- Hardware prefetcher enabled 81
- Hyper threading enabled 81
- Limit cpuid maximum disabled 81
- Server class custom 81
- Setting this item to enabled allows legacy operating system to boot even without support for cpus with extended cpuid functions configuration options disabled enabled 81
- Socket 1 cpu information 81
- This item allows you to turn on off the mid level cache l2 streamer prefetcher configuration options disabled enabled 81
- Use intel recommended prefetch settings configuration options enterprise high performance hpc custom 81
- Xp can prevent certain classes of malicious buffer overflow attacks when combined with a supporting os windows server 2003 sp1 windows xp sp2 suse linux 9 redhat enterprise 3 update 3 configuration options disabled enabled 81
- 12 chapter 5 bios setup 82
- Adjacentcachelineprefetchenabled 82
- Allows you to select apic mode configuration options autox2apic xapic 82
- Apic mode auto 82
- Cpupowermanagementconfiguration 82
- Dcu ip prefetcher enabled 82
- Dcu streamer prefetcher enabled 82
- Eist enabled 82
- Intel virtualization technology enabled 82
- Power technology custom 82
- This item allows you to enable disable intel speedstep configuration options disabled enabled 82
- This item allows you to enable disable l1 data prefetcher configuration options disabled enabled 82
- This item allows you to enable power management features configuration options disabled energy efficient custom 82
- This item allows you to turn on off prefetching of adjacent cache lines configuration options disabled enabled 82
- When enabled this item a vmm can utilize the additional hardware capabilities provided by vanderpool technology configuration options disabled enabled 82
- Cpu c3 report disabled 83
- Cpu c6 report enabled 83
- Cpu c7 report disabled 83
- Energy performance balanced performance 83
- Factory long duration maintained 1000 ms 83
- Factory long duration power limit 115 watts 83
- Long duration power limit 0 83
- P state coordination hw_all 83
- Package c state limit c6 83
- Recommended short duration power1 1 long duration 83
- Short duration power limit 0 83
- Turbo mode enabled 83
- 14 chapter 5 bios setup 84
- Chipsetconfiguration 84
- Configuration options disabled enabled 84
- Isoc enabled 84
- Qpi link frequency select auto 84
- Qpi link speed mode fast 84
- Qpi link0p disabled 84
- Qpi link0s disabled 84
- Qpi link1 enabled 84
- Qpiconfiguration 84
- This item allows for selecting the qpi link frequency configuration options auto 6 gt s 7 gt s fast mode only 8 gt s fast mode only 84
- This item allows you to select the qpi link speed as either the fast mode or slow mode configuration options slow fast 84
- Asus rs720 x7 rs8 5 15 85
- Channel interleaving auto 85
- Compatibility rid enabled 85
- Configuration options independent mirroring lock step sparing 85
- Ddr speed auto 85
- Force ddr speed configuration options auto force ddr3 800 force ddr3 1066 force ddr3 1333 force ddr3 1600 force ddr3 1866 85
- Memory mode independent 85
- Memoryconfiguration 85
- Rank interleaving auto 85
- Select different channel interleaving setting configuration options auto 1 way 2 way 3 way 4 way 85
- Select different rank interleaving setting configuration options auto 1 way 2 way 4 way 8 way 85
- Select the mode for memory initializaton 85
- Support for compatibility revision id crid functionality mentioned in sandy bridge bios specification configuration options enabled disabled 85
- Allow 2x refresh enabled 86
- Altitude 300 m 86
- Data scrambling enabled 86
- Demand scrub enabled 86
- Device tagging disabled 86
- Enable high temp disabled 86
- Memory hot sensor support enabled 86
- Patrol scrub disabled 86
- Thermal throtting cltt 86
- Allows you to decide priority between onboard and 1st offboard video device found configuration options onboard offboard 87
- Allows you to enable disable dca support configuration options disabled enabled 87
- Allows you to enable disable intel i o accelaration technology configuration options disabled enabled 87
- Asus rs720 x7 rs8 5 17 87
- Cpuiiobridgeconfiguration 87
- Dca support enabled 87
- Dimm information 87
- Intel r i oat disabled 87
- Vga priority offboard 87
- 18 chapter 5 bios setup 88
- Allows you to enable disable onboard sata raid option rom if launch storage oprom is enabled configuration options disabled enabled 88
- Allows you to enable disable patsburg scu devices 88
- Configuration options disabled enabled in s5 enabled in s4 and s5 88
- Configuration options enabled disabled 88
- Deep sx disabled 88
- Mobile platforms support deep s4 s5 in dc only and desktop platforms support deep s4 s5 in ac only 88
- Onboard sata raid oprom enabled 88
- Pch compatibility rid disabled 88
- Pchconfiguration 88
- Scu devices enabled 88
- Support for pch compatibility configuration options disabled enabled 88
- High precision timer enabled 89
- Highprecisioneventtimerconfiguration 89
- Intel r vt d disabled 89
- Intel r vtfordirectedi oconfiguration 89
- 20 chapter 5 bios setup 90
- Aggressive link power management enabled 90
- Ahci supports staggered spin up configuration options enabled disabled 90
- Allows you to set the sata configuration configuration options disabled ide mode ahci mode raid mode 90
- Configuration options enabled disabled 90
- If you want the serial ata hard disk drives to use the advanced host controller interface ahci keep the default setting ahci mode the ahci allows the onboard storage driver to enable advanced serial ata features that increases storage performance on random workloads by allowing the drive to internally optimize the order of commands 90
- If you want to create raid sets with lsi megaraid utility or inte 90
- If you want to use the serial ata hard disk drives as parallel ata physical storage devices set this item to ide mode 90
- Pchsataconfiguration 90
- Port 1 2 3 4 5 6 staggered spin up disabled 90
- Rapid storage technology enterprise from the serial ata hard disk drives set this item to raid mode 90
- S m a r t self monitoring analysis and reporting technology is a monitor system when hard disk read write errors occur this feature allows the hard disk to report warning messages during the post configuration options enabled disabled 90
- S m a r t status check enabled 90
- Sata mode ahci mode 90
- Asus rs720 x7 rs8 5 21 91
- Pchscuconfiguration 91
- This menu automatically detects and displays device 1 4 91
- 22 chapter 5 bios setup 92
- Enables or disables pci device to generate perr configuration options disabled enabled 92
- Enables or disables pci device to generate serr configuration options disabled enabled 92
- Enables or disables pci device to load rt32 image configuration options disabled enabled 92
- Enables or disables vga pallette registers snooping configuration options disabled enabled 92
- In case of multiple option roms legacy and efi compatible specifies what pci option rom to lanuch configuration options legacy rom efi compatible rom 92
- Load rt32 image disabled 92
- Pci latency timer 32 pci bus clocks 92
- Pci rom priority efi compatible rom 92
- Pci subsystem settings 92
- Perr generation disabled 92
- Serr generation disabled 92
- Value to be programmed into pci latency timer register configuration options 32 pci bus clocks 64 pci bus clocks 96 pci bus clocks 128 pci bus clocks 160 pci bus clocks 192 pci bus clocks 224 pci bus clocks 248 pci bus clocks 92
- Vga palette snoop disabled 92
- Allows to set the aspm level configuration options disabled auto force l0s force l0s force all links to l0s state auto bios auto configure disabled disabled aspm 93
- Aspm support disabled 93
- Asus rs720 x7 rs8 5 23 93
- Pci express link register settings 93
- Pci express settings 93
- 24 chapter 5 bios setup 94
- Configuration options disabled enabled 94
- Enables or disables boot option for legacy mass storage device with option rom 94
- Launch storage 0prom enabled 94
- Pcie1 option rom enabled 94
- Pcie2 option rom enabled 94
- Pcie3 option rom enabled 94
- Pcie4 option rom enabled 94
- Pcie5 option rom enabled 94
- Pcie6 option rom enabled 94
- Pcie7 option rom enabled 94
- Pcieslotoptionromconfiguration 94
- Pike option rom enabled 94
- Asus rs720 x7 rs8 5 25 95
- Install a trusted platform module tpm on the motherboard to enable the inte 95
- Inteltxt lt sx configuration 95
- This is the intel trusted execution technology txt feature vt and vt d support must be enabled before using this feature 95
- Txt lt hardware support 95
- 26 chapter 5 bios setup 96
- Device reset time out 20 sec 96
- Ehci hand off disabled 96
- Legacy usb support enabled 96
- This is a workaround for oses without ehci ownership change should be claimed by ehci driver configuration options disabled enabled 96
- This item enables or disables legacy usb device support configuration options enabled disabled auto 96
- This item sets the time out value for control bulk and interrupt transfer configuration options 1 sec 5 sec 10 sec 20 sec 96
- Usb hardware delays and time outs 96
- Usb mass storage device start unit command time out configuration options 10 sec 20 sec 30 sec 40 sec 96
- Usb transfer time out 20 sec 96
- Usbconfiguration 96
- Allows you to enable or disable onboard usb ports configuration options disabled enabled 97
- Allows you to enable or disable rear usb ports configuration options disabled enabled 97
- Allows you to enable or disable the tpm support configuration options disabled enabled 97
- Asus rs720 x7 rs8 5 27 97
- Ehci controller 1 2 enabled 97
- Onboard usb 1 2 3 4 5 6 7 enabled 97
- Rear usb 1 2 enabled 97
- Tpm support enabled 97
- Trusted computing 97
- Usb configuration the usb device will all disable in os configuration options disabled enabled 97
- Usbportsconfiguration 97
- 28 chapter 5 bios setup 98
- Acpi settings 98
- Acpi sleep state s1 cpu stop clock 98
- Allows you to enable or disable bios acpi auto configuration configuration options disabled enabled 98
- Allows you to enable or disable lock legacy resources configuration options disabled enabled 98
- Allows you to enable or disable the windows hardware error architecture support configuration options disabled enabled 98
- Allows you to set the acpi sleep state configuration options suspend disabled s1 cpu stop clock s3 suspend to ram 98
- Enable hibernation enabled 98
- Enableacpiautoconfigurationdisabled 98
- Enables or disables system ability to hibernate 0s s4 sleep state this option may be not effective with some os configuration options disabled enabled 98
- Lock legacy resources disabled 98
- The following item appears only when you set enabledacpiautoconfiguration to disabled 98
- Whea support enabled 98
- Wheaconfiguration 98
- Apm setting 99
- Power on by pcie disabled 99
- Power on by ring disabled 99
- Power on by rtc disabled 99
- Restore ac power loss last state 99
- 30 chapter 5 bios setup 100
- Ansi extended ascii char set 100
- Bits per second 57600 selects serial port transmission speed the speed must be matched on the other side long or noisy lines may require lower speeds configuration options 9600 19200 38400 57600 115200 100
- Com1 console redirection disabled 100
- Console redirection settings 100
- Enables or disables the console redirection feature configuration options disabled enabled 100
- Serial port console redirection 100
- Terminal type vt utf8 allows you to set the terminal type 100
- The following item appears only when you set console redirection to enabled 100
- This item becomes configurable only when you enable the console redirection item the settings specify how the host computer and the remote computer which the user is using will exchange data both computers should have the same or compatible settings 100
- Vt utf8 uses utf8 encoding to map unicode chars onto 1 or more bytes 100
- Vt100 ascii char set 100
- Vt100 extends vt100 to support color function keys et 100
- Com2 console redirection enabled 101
- Console redirection settings 101
- Console redirection disabled 102
- Console redirection settings 102
- Serial port for out of band management windows emergency management services ems 102
- Asus rs720 x7 rs8 5 33 103
- Configuration options disabled enabled 103
- Enables or disables intel lan1 function configuration options disabled enabled 103
- Enables or disables intel lan2 function configuration options disabled enabled 103
- Enables or disables intel lan3 function configuration options disabled enabled 103
- Enables or disables intel lan4 function configuration options disabled enabled 103
- Intel lan rom type pxe 103
- Intel lan1 enable enabled 103
- Intel lan2 enable enabled 103
- Intel lan3 enable enabled 103
- Intel lan4 enable enabled 103
- Lan1 option rom support enabled 103
- Lan2 option rom support enabled 103
- Lan3 option rom support enabled 103
- Lan4 option rom support enabled 103
- Onboardlanconfiguration 103
- This item launches lan rom configuration options disabled pxe iscsi 103
- 34 chapter 5 bios setup 104
- Allows you to change the serial port mode configuration options standard serial port mode 104
- Allows you to enable or disable the serial port configuration options disabled enabled 104
- Device mode standard serial port mode 104
- Legacydevicesconfiguration 104
- Me subsystem 104
- Serial port enabled 104
- Serialport1 2configuration 104
- Allows you to enable or disable pci error logging configuration options disabled enabled 105
- Pci error logging support disabled 105
- Runtime error logging 105
- Runtime error logging support disabled 105
- This item allows you to enable or disable runtime error logging support configuration options disabled enabled 105
- 36 chapter 5 bios setup 106
- Allows you to configure how the system should respond if the os boot watchdog timer expires not available if o s boot watchdog timer is disabled configuration options do nothing reset power down 106
- Allows you to configure the length of the o s boot watchdog timer not available if o s boot watchdog timer is disabled configuration options 5 minutes 10 minutes 15 minutes 20 minutes 106
- If enabled starts a bios timer which can only be shut off by intel management software after the os loads helps determine that the os sucessfully loaded or follows the o s boot watchdog timer policy configuration options enabled disabled 106
- O s watchdog timer disabled 106
- O s wtd timer policy reset 106
- O s wtd timer timeout 10 minutes 106
- Server mgmt menu 106
- The server mgmt menu appears only when you install asmb card on the motherboard 106
- The server mgmt menu displays the server management status and allows you to change the settings 106
- All values changed here do not take effect until computer is restarted 107
- Allows you to choose options for erasing sel configuration options no yes on next reset yes on every reset 107
- Allows you to choose options for reactions to a full sel configuration options do nothing erase immediately 107
- Allows you to enable or disable all features of system event logging during boot configuration options disabled enabled 107
- Asus rs720 x7 rs8 5 37 107
- Erase sel no 107
- Sel components disabled 107
- System event log 107
- The following items appears only when you set sel components to enabled 107
- When sel is full do nothing 107
- 38 chapter 5 bios setup 108
- Bmcnetworkconfiguration 108
- Configurationaddresssourcepreviousstate 108
- Gateway ip address 0 allows you to key in gateway ip address 108
- Select to configure lan channel parameters statically or dynamically by bios or bmc unspecified option will not modify any bmc network parameters during bios phase configuration options previous state static mode dhcp mode 108
- Station ip address 0 allows you to key in station ip address 108
- Subnet mask 0 allows you to key in subnet mask 108
- The following items appears only when you set configurationaddresssource to static mode 108
- All the changes made will take effect after you restart your system 109
- Asus rs720 x7 rs8 5 39 109
- Change smbios event log settings 109
- Enabling disabling options smbios event log enabled change this to enable or disable all features of smbios event logging during boot configuration options disabled enabled 109
- Erasing settings erase event log no choose the options for erasing smbios event log erasing is done prior to any logging activation during reset configuration options no yes next reset yes every reset 109
- Event logs menu 109
- The event logs allows you to change or view the event log settings 109
- To change the smbios event log configuration 109
- View smbios event log 110
- View system event log 110
- Allows you to enable or disable the full screen logo display feature configuration options disabled enabled 111
- Allows you to select the power on state for the numlock configuration options off on 111
- Allows you to set the display mode for options rom configuration options force bios keep current 111
- Always do not allow disable ga20 this option is useful when any rt code is executed above 1mb 111
- Asus rs720 x7 rs8 5 41 111
- Boot menu 111
- Bootup numlock state on 111
- Csm16 module version gatea20 active upon request 111
- Full screen logo enabled 111
- Keys to adjust the number of seconds to wait for setup activation key 111
- Option rom messages force bios 111
- Set this item to enabled to use the asus mylogo2 feature 111
- Setup prompt timeout xx 111
- The boot menu items allow you to change the system boot options 111
- Upon request ga20 can be disabled using bios services 111
- Boot device seeking endless pxe 112
- Boot option priorities 112
- Interrupt 19 capture enabled 112
- Uefi boot disabled 112
- Asus rs720 x7 rs8 5 43 113
- Cpu 1 2 tr1 1 2 temperature xxxºc xxxºf 113
- Cpu fan1 2 speed frnt fan1 4 speed rear fan1 2 speed xxxx rpm or n a 113
- Monitor menu 113
- Scroll down to display the following items 113
- The monitor menu displays the system temperature power status and allows you to change the fan settings 113
- The onboard hardware monitor automatically detects and displays the cpu and motherboard component temperatures 113
- The onboard hardware monitor automatically detects and displays the speed of cpu fans front fans and rear fan in rotations per minute rpm if the fan is not connected to the motherboard the field shows n a 113
- The onboard hardware monitor automatically detects the voltage output through the onboard voltage regulators 113
- Vtt_cpu voltage vcore1 2 voltage vddq_ab cd_cpu1 voltage vddq_ef gh_cpu2 voltage 5vsb voltage 5v voltage 12v voltage 3 v voltage vbat voltage 3 vsb voltage 113
- Administrator password 114
- Fan speed control generic mode 114
- Security menu 114
- Asus ez flash 2 utility 115
- Tool menu 115
- User password 115
- 46 chapter 5 bios setup 116
- A confirmation window appears select yes to discard changes and exit 116
- A confirmation window appears select yes to load optimized defaults 116
- A confirmation window appears select yes to save changes and exit 116
- Discard changes exit 116
- Discard changes reset 116
- Exit menu 116
- From the legend bar to exit 116
- Restore defaults 116
- Save changes reset 116
- The exit menu items allow you to save or discard your changes to the bios items 116
- This option allows you to reset the setup program without saving your changes when you select this option a confirmation window appears select yes to discard changes and reset 116
- Boot override 117
- Launchefishellfromfilesystemdevice 117
- Chapter 6 119
- Raidconfiguration 119
- Installing hard disk drives 120
- Raiddefinitions 120
- Setting up raid 120
- Raid controller selection 121
- Setting the raid item in bios 121
- Lsisoftwareraidconfigurationutility 122
- Creating a raid set 123
- Usingeasyconfiguration 123
- 6 chapter 6 raid configuration 124
- Bios version a 0 9231523r 124
- Lsi software raid configuration utility ver c 5 sep 17 2010 124
- Onlin a00 00 124
- Onlin a00 01 124
- Port 2 disk 74 4gb hds728080pla380 05 1c05 124
- The information of the selected hard disk drive displays at the bottom of the screen 124
- To configure array setting 124
- To select the configurable array 124
- When selected the drive indicator changes from ready to onlin ax y where x is the array number and y is the drive number 124
- You need at least four identical hard disk drives when creating a raid 10 set 124
- You need at least two identical hard disk drives when creating a raid 1 set 124
- 148 80gb 2 64 kb online 125
- Again the virtual drive information appears including a virtual drive menu that allows you to change the virtual drive parameters 125
- Asus rs720 x7 rs8 6 7 125
- Bios version a 0 9231523r 125
- Ld raid size stripes stripsz status 125
- Lsi software raid configuration utility ver c 5 sep 17 2010 125
- 148 80gb 2 64 kb online 126
- 8 chapter 6 raid configuration 126
- Bios version a 0 9231523r 126
- Enabling dwc can improve the performance but with the risk of data loss 126
- Ld raid size stripes stripsz status 126
- Lsi software raid configuration utility ver c 5 sep 17 2010 126
- When creating a raid 1 or a raid 10 set select dwc from the virtual 126
- When creating a when creating a raid 0 set proceed to step 12 126
- 148 80gb 2 64 kb online 127
- Asus rs720 x7 rs8 6 9 127
- Bios version a 0 9231523r 127
- Follow step 2 to 12 to configure additional virtual drives 127
- Ld raid size stripes stripsz status 127
- Lsi software raid configuration utility ver c 5 sep 17 2010 127
- To finish raid configuration when prompted to save 127
- Use cursor keys to navigate between items and press enter to select an option 127
- When finished setting the selected virtual drive configuration select accept 127
- 10 chapter 6 raid configuration 128
- 148 80gb 2 64 kb online 128
- Follow step 10 to 14 of the previous section usingeasyconfiguration to create the raid set 128
- Follow step 2 to 9 of the previous section usingeasyconfiguration 128
- Ld raid size stripes stripsz status 128
- To create a raid set using the newconfiguration option 128
- Usingnewconfiguration 128
- When a raid set already exists using the newconfiguration command erases the existing raid configuration data if you do not want to delete the existing raid set use the view addconfiguration command to view or create another raid configuration 128
- Addinganewraidconfiguration 129
- Addingorviewingaraidconfiguration 129
- Initializing the virtual drives 130
- Using the initialize command 130
- 100 completed 131
- 148 80gb 2 64 kb online 131
- Asus rs720 x7 rs8 6 13 131
- Bios version a 0 9231523r 131
- Init of vd is in process 131
- Initializing a virtual drive erases all data on the drive 131
- Ld raid size stripes stripsz status 131
- Ld raid size stripes stripsz status 0 10 154494mb 4 64 kb online 131
- Lsi software raid configuration utility ver c 5 sep 17 2010 131
- Space de select f10 initialize 131
- Vd 0 initialization complete press esc 131
- Virtual drive 0 131
- Virtual drive s configured 131
- 14 chapter 6 raid configuration 132
- Bios version a 0 9231523r 132
- Lsi software raid configuration utility ver c 5 sep 17 2010 132
- To initialize the virtual drives using the objects command 132
- Usingtheobjectscommand 132
- Asus rs720 x7 rs8 6 15 133
- Bios version a 0 9231523r 133
- Init will destroy data on selected vd s 133
- Initilize vd 133
- Lsi software raid configuration utility ver c 5 sep 17 2010 133
- To start initialization 133
- 16 chapter 6 raid configuration 134
- Rebuilding failed drives 134
- To rebuild a failed hard disk drive 134
- You can manually rebuild failed hard disk drives using the rebuild command in the management menu 134
- Asus rs720 x7 rs8 6 17 135
- Bios version a 0 9231523r 135
- Lsi software raid configuration utility ver c 5 sep 17 2010 135
- To rebuild the drive 135
- When rebuild is complete press any key to continue 135
- Checking the drives for data consistency 136
- Using the check consistency command 136
- Usingtheobjectscommand 138
- Asus rs720 x7 rs8 6 21 139
- Bios version a 0 9231523r 139
- Deletingaraidconfiguration 139
- Lsi software raid configuration utility ver c 5 sep 17 2010 139
- Press any key to continue 139
- The utility clears all the current array s the utility clears all the current array s 139
- To delete a raid configuration 139
- 22 chapter 6 raid configuration 140
- Bios version a 0 9231523r 140
- Lsi software raid configuration utility ver c 5 sep 17 2010 140
- Selecting the boot drive from a raid set 140
- The virtual drive is selected as boot drive press any key to continue 140
- To select the boot drive from a raid set 140
- You must have created a new raid configuration before you can select the boot drive from a raid set see section 6 creating a raid set using new configuration for details 140
- Asus rs720 x7 rs8 6 23 141
- Bios version a 0 9231523r 141
- Enabling writecache 141
- Lsi software raid configuration utility ver c 5 sep 17 2010 141
- The writecache function is recommended for raid 1 and raid 10 sets 141
- To display the adapter properties 141
- To enable writecache 141
- To turn on the option 141
- When finished press any key to continue 141
- When you enable writecache you may lose data when a power interruption occurs while transmitting or exchanging data among the drives 141
- You may manually enable the raid controller s writecache option after creating a raid set to improve the data transmission performance 141
- 24 chapter 6 raid configuration 142
- Install all the serial ata hard disk drives 142
- Option rom utility 142
- Raid 1 raid 10 raid 1 0 and raid 5 set s from serial ata hard disk drives that are connected to the serial ata connectors supported by the southbridge 142
- Rapid storage technology 142
- Rapid storage technology option rom utility 142
- Rapid storage technology option rom utility allows you to create raid 142
- The intel 142
- The navigation keys at the bottom of the screen allow you to move through the navigation keys at the bottom of the screen allow you to move through the menus and select the menu options 142
- The raid bios setup screens shown in this section are for reference only and may not exactly match the items on your screen 142
- To display the utility main menu 142
- To enter the intel 142
- Turn on the system 142
- After completing your selection 143
- Asus rs720 x7 rs8 6 25 143
- Creating a raid set 143
- The following screen appears 143
- To create a raid set 143
- To select the hard disk drives you want to include in the raid set the select disks screen appears 143
- Creating a recovery set 144
- 28 chapter 6 raid configuration 146
- Deleting a raid set 146
- Take caution when deleting a raid set you will lose all data on the hard disk drives when you delete a raid set 146
- The following screen appears 146
- The following warning message appears 146
- To delete a raid set 146
- To return to the delete volume menu 146
- Asus rs720 x7 rs8 6 29 147
- Resetting disks to non raid 147
- Take caution before you reset a raid volume hard disk drive to non raid resetting a raid volume hard disk drive deletes all internal raid structure on the drive 147
- The following screen appears 147
- To reset a raid set hard disk drive 147
- To reset the raid set drive s a confirmation message appears 147
- To return to the utility main menu 147
- To select 147
- 30 chapter 6 raid configuration 148
- After completing your selection and return to the utility main menu 148
- If you have created a recovery set you can configure more recovery set options following the descriptions in the section 148
- Recovery volume options 148
- See section 6 creating a recovery set to create a recovery set before continue 148
- The following screen appears 148
- The select recovery volume screen appears 148
- To configure a recovery set 148
- Asus rs720 x7 rs8 6 31 149
- Exiting the intel 149
- If any of the sata hard disk drives included in the raid 1 array failed the system displays the status of the raid volume as degraded during post you can rebuild the raid array with other installed non raid disks 149
- Rapid storage technology utility 149
- Rebuilding the raid 149
- Rebuilding the raid with other non raid disk 149
- Select a destination disk with the same size as the original hard disk 149
- The following warning message appears 149
- This option is only for the raid 1 set 149
- To enter the intel rapid storage technology option rom utility 149
- To exit 149
- To exit the utility 149
- To rebuild the raid with other non raid disk 149
- To return to the utility main menu 149
- 32 chapter 6 raid configuration 150
- Exit intel rapid storage technology and reboot the system 150
- From the view menu select advanced mode to display the details of the intel rapid storage console 150
- From the volumes view option select raid volume to view the rebuilding status when finished the status is changed to normal 150
- If any of the sata hard disk drives included in the raid array failed the system displays the status of the raid volume as degraded during post you may replace the disk drive and rebuild the raid array 150
- Intelrapidstorage console or click the intel rapid storage technology tray icon to load the intel rapid stroage manager utility 150
- Reboot the system and then follow the steps in section rebuilding the raid with other non raid disk 150
- Rebuilding the raid with a new hard disk 150
- Remove the failed sata hard disk and install a new sata hard disk of the same specification into the same sata port 150
- Select a destination disk with the same size as the original hard disk 150
- The utility immediately starts rebuilding after the disk is selected the status of the degraded raid volume is changed to rebuild 150
- To rebuild the raid with a new hard disk 150
- Setting the boot array in the bios setup utility 151
- Chapter 7 153
- Driver installation 153
- C600 intel raid driver 154
- Creating a raid driver disk 154
- Raid driver installation 154
- Follow screen instructions to create the driver disk 155
- Locate the raid driver and place a blank high density floppy disk to the floppy disk drive 155
- Lsi 2008 sas2 driver 155
- During window 157
- Installing the raid controller driver 157
- Server 2008 os installation 157
- Enterprise linux os 5 159
- Red ha 159
- Enterprise linux os 6 161
- Red ha 161
- 10 chapter 7 driver installation 162
- Preparing the linux driver 164
- Suse linux 11 os 165
- Chipset device software 167
- Installation 167
- Network connections software installation 170
- Vga driver installation 173
- C600 series chipset scu sata raid drivers 176
- Rapid storage technology enterprise 3 installation 177
- Wg82574l gigabit adapters driver installation 180
- Drivers menu 184
- Management applications and utilities installation 184
- Place the support dvd to the optical drive the dvd automatically displays the drivers menu if autorun is enabled in your computer 184
- Running the support dvd 184
- The drivers menu shows the available device drivers if the system detects installed devices install the necessary drivers to activate the devices 184
- The support dvd that came with the motherboard package contains the drivers management applications and utilities that you can install to avail all motherboard features 184
- Contact information 185
- Make disk menu 185
- Utilities menu 185
- Asus contact information 187
- Asustek computer inc 187
- Asustek computer inc china 187
- Asustek computer inc taiwan 187
- Technical support 187
- Asus computer gmbh germany and austria 188
- Asus computer international america 188
- Asus contact information 188
- Technical support 188
Похожие устройства
- Asus pike 2008 Инструкция по эксплуатации
- Asus pike 2008 Инструкция по эксплуатации
- Asus n56jr Инструкция по эксплуатации
- Asus X751LD Инструкция по эксплуатации
- Asus x551ma Инструкция по эксплуатации
- Asus x751la Инструкция по эксплуатации
- Asus rog swift pg278q Инструкция по эксплуатации
- Asus j1800i-c Инструкция по эксплуатации
- Teac TN-300 Black Инструкция по эксплуатации
- Technics SC-HD560 EP-N Инструкция по эксплуатации
- Technics SC-EH790 EP-S Инструкция по эксплуатации
- Techpoint 47 DVD Leo Pl Sl Инструкция по эксплуатации
- Teckton TD-250 RUS Инструкция по эксплуатации
- Teckton TD-200X RUS Инструкция по эксплуатации
- Tefal 91487 Инструкция по эксплуатации
- Tefal 91110 Инструкция по эксплуатации
- Asus j1800i-a Инструкция по эксплуатации
- Asus z97-ar Инструкция по эксплуатации
- Asus memo pad 7 me176сx 16gb white Инструкция по эксплуатации
- Asus zenbook ux32ln Инструкция по эксплуатации