Yealink SIP-T46G Инструкция по работе с сервером Autoprovision онлайн [398/401] 166934

Yealink SIP-T40P Инструкция по работе с сервером Autoprovision онлайн [398/401] 166937
Yealink IP Phones Auto Provisioning Guide
388
BLF LED Mode provides four kinds of definition for the BLF/BLF list key LED status. The
following tables list the LED statuses of the BLF/BLF list key when BLF LED Mode is set to 0,
1, 2 or 3 respectively. The default value of the BLF LED Mode is 0. BLF LED Mode is not
applicable to SIP-T48G IP phones. BLF/BLF list key LED status for line keys on
T46G/T42G/T41P IP phones are the same as that for memory keys.
Line key LED (configured as a BLF/BLF list key and BLF LED Mode is set to 0)
LED Status
Description
Solid green
The monitored user is idle.
Fast flashing green (200ms)
The monitored user receives an incoming call.
Slow flashing green (500ms)
The monitored user is dialing.
The monitored user is talking.
The monitored user’s conversation is placed on
hold (This LED status requires server support).
Slow flashing green (1s)
The call is parked against the monitored users
phone number.
Off
The monitored user does not exist.
Memory key/Expansion Module key LED (configured as a BLF/BLF list key and BLF LED
Mode is set to 0)
LED Status
Description
Solid green
The monitored user is idle.
Fast flashing red (200ms)
The monitored user receives an incoming call.
Solid red
The monitored user is dialing.
The monitored user is talking.
The monitored user’s conversation is placed on
hold (This LED status requires server support).
Slow flashing red (1s)
The call is parked against the monitored users
phone number.
Off
The monitored user does not exist.
Line key LED (configured as a BLF/BLF list key and BLF LED Mode is set to 1)
LED Status
Description
Fast flashing green (200ms)
The monitored user receives an incoming call.
Solid green
The monitored user is dialing.
The monitored user is talking.
The monitored user’s conversation is placed on
hold (This LED status requires server support).