Yealink SIP-T40P — настройка расширенных функций для телефонных интерфейсов [447/841]

Yealink SIP-T19P E2 Руководство администратора онлайн [447/841] 166997
Configuring Advanced Features
431
Parameters
Permitted
Values
Default
Web User Interface:
DSSKey->Line Key->Line
Phone User Interface:
Menu->Features->DSS Keys->Line Key X->Account ID
linekey.X.value/
expansion_module.X.key.Y.value
String within
99 characters
Blank
Description:
Configures the number of the monitored user.
For line keys:
X ranges from 1 to 29 (for SIP-T48G)
X ranges from 1 to 27 (for SIP-T46G/T29G)
X ranges from 1 to 15 (for SIP-T42G/T41P)
X ranges from 1 to 21 (for SIP-T27P)
X ranges from 1 to 3 (for SIP-T23P/G)
X ranges from 1 to 2 (for SIP-T21(P) E2)
For ext keys:
X ranges from 1 to 6, Y ranges from 1 to 20, 22 to 40 (Ext key 21 cannot be
configured).
Example:
linekey.1.value = 1008
Note: It is not applicable to SIP-T19(P) E2 IP phones.
Web User Interface:
DSSKey->Line Key->Value
Phone User Interface:
Menu->Features->DSS Keys->Line Key X->Value
linekey.X.pickup_value/
expansion_module.X.key.Y.pickup_value
String within
256
characters
Blank
Description:
Configures the pickup code for BLF feature.
This parameter only applies to BLF feature.
For line keys:
X ranges from 1 to 29 (for SIP-T48G)

Содержание