Support Cable:
Single mode: 8.3/125, 8.7/125, 9/125 or 10/125 μm
Multimode: 50/125, 62.5/125, or 100/140 μm
Wavelength
ICF-1150-S: 1310 nm
ICF-1150-M: 850 nm
TX Output
ICF-1150-S: > -5 dBm
ICF-1150-M: > -5 dBm
RX Sensitivity
ICF-1150-S: -25 dBm
ICF-1150-M: -20 dBm
Point-to-Point Transmission
Half or Full duplex
Multi-drop Transmission
Half duplex, fiber ring
Environmental
Operating Temperature
0 to 60°C (32 to 140°F), 5 to 95 % RH
-40 to 85°C (-40 to 185°F) for T Model
Storage Temperature
-40 to 85°C (-40 to 185°F), 5 to 95 % RH
Power
Input Power Voltage
12 to 48 VDC, 300 mA (Max.) Class 2
Power Line Protection
4 kV Burst (EFT), EN61000-4-4
2 kV Surge, EN61000-4-5
Reverse Power Protection
Protects against V+/V- reversal
Over Current Protection Protects against 2 signals shorted
together: 1.1 A
Power Consumption
ICF-1150-S/M-SC/ST: 127 mA @ 12 V
ICF-1150I-S/M-SC/ST: 163 mA @ 12 V
Physical Characteristics
Dimensions (W × D × H)
30.3 × 70 × 115 mm
Material
Aluminum (1 mm)
Gross Weight
135 g
Regulatory Approvals
CE
Class B
FCC
Part 15 sub Class B
LVD
EN 60950-1
EMI
EN55022 1998, Class B
EMS
EN61000-4-2 (ESD), Criteria B, Level 4
EN61000-4-3 (RS), Criteria A, Level 3
EN61000-4-4 (EFT), Criteria B, Level 4
EN61000-4-5 (Surge), Criteria A, Level 3
EN61000-4-6 (CS), Criteria A, Level 3
En61000-4-8 (PFMF), Criteria A, Level 5
Freefall
IEC 60068-2-32
MTBF
792085 hrs
Hazardous Certifications
ATEX
10 ATEX 0917344X
IECEx
IECEx UL 13.0034X
Technical Support Contact Information
www.moxa.com/support
Moxa Americas:
Toll
-free: 1-888-669-2872
Tel:
+1-714-528-6777
Fax:
+1-714-528-6778
Moxa China (Shanghai office):
Toll
-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Europe
:
Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa Asia
-Pacific:
Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231

Похожие устройства

Скачать