Timberk TEC.PS1 EL 10 IN Инструкция по эксплуатации онлайн [6/16] 10701

Содержание

Похожие устройства

Illllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiimiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiim Hiiiiiiiiiiiliiii ENGLISH show and ON symbols 6 4 The convector will be switched on to operate in the economy mode afterthe timer expires and will maintain the set temperature 7 Lock 7 1 When the convector is operating to lock the system simultaneously press and hold A and buttons for 3 seconds after that ESI symbol will be shown on the remote controller s display 7 2 To unlock the system press and hold A or buttons for 3 seconds 8 Air ionizing function 8 1 To activate the air ionizing function press ION button at that ION symbol will be shown on the remote controller s display 8 2 To deactivate the air ionizing function press ION button at that ION symbol will disappear from the remote controller s display O NOTE A small static electric charge may be accumulated on metal surfaces of a case in units equipped with an air ionizer If your electric main has no grounding circuit or it is damaged In this case there is a small possibility of electric shock from static voltage 9 Convector switching off To switch off the convector press and hold POWER button on the remote controller for 3 seconds lllllllllllllllllllllllllllllllllllllllllllllllllllllllll llllllllllllll l llllllllllllllllillllllllllliillllllllllllltlll llllllllllllllllllll l IIIIIIIIIIIIIIM IMPORTANT If the unit is operated without a grounding circuit or it is damaged it is not recommended to switch on and operate the air k ionizer O TEC PS1 PGE IN series control panel Fig 11 4 10 3 8 www timberk com electric convector heater Fig 11 i H timer button It is used to activate the timer function to switch off on the convector heater 2 Timer indicator It is illuminated when the convector switch off on timer function is activated 3 f button It is used to switch on off the air ionizing function 4 Ionizer air ionizer indicator It is illuminated when the air ionizing function is activated 5 Power indicator It is illuminated at turning on the power switch when the unit is connected to electric mains 6 Economy mode indicator It is illuminated when the convector heater is operating in the economy mode 7 Normal comfort mode indicator It is illuminated when the convector heater is operating in the comfort mode 8 LCD display LCD display can show temperature and time settings heating power modes timer settings as well as running programs To switch the display from time indication to temperature press and hold E button for 3 seconds heating temperature selection button It is used to set heating temperature in the comfort and economy operation modes 10 Button O It is used to increase the selected value 11 Button Q It is used to decrease the selected value 12 E programming button It is used to select preset programs and program a user program for the week 13 Button It is used to select the following operation modes low power symbol high power w symbol 14 Button 3 It is used to copy settings 15 Power switch It is used to switch on off the convector heater 1 Switch on the convector Connect the convector to electric mains by plugging the power cord into an electric outlet set the power switch located on the side of the control panel to position ON at that red power indicator Power will be illuminated on the control panel a sound signal will be given and symbols will be shown on the display 2 Time setting 2 1 When the convector heater is operating press button two times at that the hours setting will start blinking By means of Q and Ki buttons set hours required at the moment in increments of 1 hour from 0 to 24 hours 2 2 After hours are set press button again to set minutes at that the minutes setting start blinking By means of O and KJ buttons set minutes required at the moment in increments of 1 minute from 0 to 59 minutes 2 3 After minutes are set press H button again to set the day of week at that the day symbol start blinking Bymeansof O and buttons set the day of week While selecting the day of week the following symbols will beshown Mon Tue Wed Thu Fri Sat Sun 3 Heating power mode selection Press button e once to enter power selection By means of 0 and D buttons set high heating power or low heating power When device is working under high power at that w symbol will be shown on the display When device is working under low power at that w symbol will be shown on the display 4 Temperature setting 4 1 Temperature can be set within the range 5 to 30 C in increments of 1 C 4 2 Factory setting of the comfort mode temperature is 24 C factory setting of the economy mode temperature is 17 C 4 3 To change the economy mode temperature press G3 button once at that ft symbol will be shown on the display and value of the last set temperature will start blinking and orange Normal comfort mode indicator will be illuminated on the control panel While the temperature setting is blinking press button Q or KI to set the desired temperature 4 4 To change the comfort mode temperature press Q button twice at that Ul symbol will be shown on the display and value of the last set temperature will start blinking and green Economy mode indicator will be illuminated on the control panel While the temperature setting is blinking press button Jfl or O to set the desired temperature 5 Antifreeze mode Press E button three times to select the antifreeze mode at that symbol will be displayed The convector heater will automatically maintain temperature within 5 C to 7 C switching on and off heating from time to time 6 Description of operation programs The convector heater has 12 factory preset weekly operation programs P1 to P12 programs and one user program with an opportunity to program operation modes for a week DIY program Description ofweekly operation programs is given inTable 3 where W is execution of the program during working days Monday Tuesday Wednesday Thursday Friday SA is execution of the program on Saturday SU is execution of the program on Sunday is the symbol for comfort mode operation w isthe symbol foreconomy mode operation Table 3 w ra i N Jiiiiiiuri i ________ r Tt Xi ir 1 J SA SU i ___ _____ i i ri str ttar i i xtâs tBiJsr re w r jr z ___ 1 Available programs as perTable 3 P 01 comfort mode heating at noon and in the evening P 02 comfort mode heating in the morning at noon and in the evening P 03 comfort mode heating with altered interval in the morning on working days in comparison with P 02 program P 04 comfort mode heating taking into account presence at home during the entire day P 05 comfort mode heating on working days taking into account breaks www timberk com electric convector heater 11

Скачать