Type Output
stages
[kW]
Airflow
[m
3
/h]
Sound
level*
1
[dB(A)]
t*
2
[°C]
Voltage [V]
Amperage [A]
(control)
Voltage [V]
Amperage [A]
(heat)
Length
[mm]
Weight
[kg]
RD18E09 (or RD310E09) 0/6/9 1800 54 15 230V~/2,52A 400V3~/13A 1000 45
(RD315E12) 0/8/12 2500 55 14 230V~/2,52A 400V3~/17,5A 1500 76
(RD320E18) 0/12/18 3600 56 15 230V~/4,20A 400V3~/26A 2000 106
(RD325E18) 0/12/18 4400 57 12 230V~/5,04A 400V3~/26A 2500 138
RD27E15 (or RD410E15) 0/10/15 2700 55 17 230V~/3,36A 400V3~/22A 1000 45
RD365E23 (or RD415E23) 0/15/22,5 3600 56 19 230V~/4,48A 400V3~/32,5A 1500 77
RD54E30 (or RD420E30) 0/20/30 5400 57 17 230V~/6,72A 400V3~/43,5A 2000 107
RD63E36 (or RD425E36) 0/24/36 6300 58 17 230V~/7,84A 400V3~/52A 2500 138
*1) Conditions: Distance to the unit 3 metres. Equivalent absorption area 50 m
2
.
*2) t = temperature rise of passing air at maximum heat output and highest airflow.
Technical specifications | Thermozone RD E