UP-308FEW / UP-316FEW
System Priority: A value that identifies the active LACP. The switch with the lowest value
has the highest priority and is selected as the active LACP peer of the trunk group.
Link Aggregation Algorithm: Select the algorithm of link aggregation. The available options are:
• MAC Src&Dst – Hash Algorithm based on Source & Destination MAC Address XOR result.
• MAC Src – Hash Algorithm based on Source MAC Address
The default setting is MAC Src&Dst.
Member: Select the ports that will be the members of link aggregation group. Default link
group 1 includes P1, P2, P3, P4. Default link group 2 includes P5, P6, P7, P8.
State: Disable / Enable port trunk. The default setting is Disable.
Type: Select port trunk type: Static or LACP (Dynamic). The default setting is LACP.
When the LACP Trunk type is selected, the following parameters can be configured. Please
note that the parameters of ports that belong to one link aggregation group should be the
same on both ends.
Operation Key: Range: 1~65535. Default Link Group 1: 1; Default Link Group 2: 2.
Time Out: Select Long Time Out or Short Time Out. The Long Time Out is approximately
30 seconds, the Short Time Out is approximately 3 seconds, however, the link partner of
other supplier may not use the same value. The longer time out then will be used.
Activity: Select whether the link group is allowed (Active) to automatically send LACP
packets or not (Passive). The default setting is Passive.
User Manual 42
Содержание
66- Table of contents
- Up 316few up 316few
- Up 308few
- Product overview
- Package contents
- Features
- Rear panel
- Front panel of up 316few
- Front panel of up 308few
- External components description
- Led description
- Installation
- Rack mounting
- Power connection
- Installation site requirements
- Desktop installation
- Connecting to end nodes
- Accessing the switch web management gui
- Administrator
- Authentication configuration
- Switch configuration
- System ip configuration
- System status
- Load default setting
- Reboot device
- Firmware update
- Poe status
- Poe setting
- Poe power delay
- Poe scheduling
- Port management
- Port configuration
- Port mirroring
- Bandwidth control
- Broadcast storm control
- Vlan setting
- Vlan mode
- Vlan member
- Multi to 1 setting
- Per port counter
- Qos setting
- Priority mode
- Class of service
- Security
- Mac address binding
- Tcp udp filter
- Web security
- Spanning tree
- Stp bridge settings
- Stp port settings
- Loopback detection
- Trunking
- Dhcp relay agent
- Vlan map relay agent
- Relay server
- Backup recovery
- Miscellaneous
- Snmp settings
- Logout
- Specifications
- User manual 50
- Up 308few up 316few
- Up 308few
- Up 308few up 316few
- User manual 51
- Up 316few
Похожие устройства
-
Upvel UP-316FEWРуководство по эксплуатации -
Upvel UP-308FEWРуководство по использованию -
Upvel UP-236FEFРуководство по быстрой установке -
Upvel UP-219FEFРуководство по быстрой установке -
Upvel UP-216FEРуководство по быстрой установке -
Upvel UP-316FEWРуководство пользователя -
Gigalink GL-SW-F005-16PПодробное техническое описание -
Gigalink GL-SW-F005-04PТехническая спецификация -
Osnovo SW-80800-IRИнструкция по эксплуатации -
Osnovo SW-80800-IRПаспорт -
Osnovo SW-80402-IИнструкция по эксплуатации -
Osnovo SW-80402-IПаспорт
Узнайте, как настроить агрегацию ссылок и приоритеты в сетевых устройствах. Пошаговое руководство по выбору алгоритмов и параметров агрегации.