Timberk swh re11 100 v Инструкция по эксплуатации онлайн [8/40] 200911
![Timberk swh re11 100 v Инструкция по эксплуатации онлайн [8/40] 200911](/views2/1239330/page8/bg8.png)
www.timberk.com • electrical storage water heater
8
NOTE:
In places or on the wall, where there may be a water
contact, the power outlet installation height must be
not less than 1.8 m.
NOTE:
The water heater is an appliance, operating in such
a manner that pressure of water in the water heater
corresponds to the pressure of water in water main.
If pressure in the main exceeds 0.8 MPa, then it is
necessary to mount a pressure reducer before the water
heater so that pressure doesn’t exceed 0.8 MPa.
NOTE:
Do not mount additional accessories, such as a shut-off
valve, between the relief valve and the inlet nozzle.
Connection to water main
1. The heater must be connected to water main with at least 0.1 MPa
pressure; maximum pressure is 0.75 MPa.
2. G1/2 diameter pipes are used to connect the water heater to the water
pipeline.
3. To prevent a leakage when connecting pipes, use rubber sealing gaskets
on the threaded pipe ends.
4. Screw a relief valve to the inlet nozzle, marked blue and embossed arrow
of the water flow direction, so that the water flow direction coincides with
direction of the arrow on the valve’s case.
5. Water heater with the mounted valve must be connected to the water
main – install a shut-off valve at the water inlet point. You need to connect
a drain pipe to the opening of the pressure relief of safety valve. Next you
should put a drain pipe to the sewer.
6. Connect the desired number of consumption points to the outlet nozzle,
marked red.
7. Open the shut-off tap and one of the tap assemblies. After the tank is
filled with water, as evidenced by issue of water from the cock assembly,
shut the cock assembly and check the leak integrity of all joints.
Connection to electric main
IMPORTANT!
If water in the installation location contains a large
amount of calcium, manganese or iron salts, then
necessary to mount a respective filter in the delivery
system to reduce the amount of scale generated in
the tank and on the heating element.
IMPORTANT!
Prior to connecting the tank water heater, make sure
that the water heater is properly grounded. Proper
grounding is important to minimize electric shocks
and risk of fire. The power cord is equipped with a plug
with a grounding pin. The appliance must be used
with a properly grounded power outlet. If the outlet,
you are intending to use, is not properly grounded or
grounded by a time-delay fuse or a circuit breaker,
contact a qualified electrician to install a proper outlet.
securely tighten bolt nuts, then hang the water heater on these anchor bolt
hooks (see Fig. 7).
3. Fix a power outlet to the wall. Requirements to the outlet are as follows:
220V/10A, single-phase, three-wired. It is recommended to place the outlet
on the right side above the water heater.
Похожие устройства
- Timberk swh re11 80 v Инструкция по эксплуатации
- Timberk swh re11 50 v Инструкция по эксплуатации
- Timberk swh re11 30 v Инструкция по эксплуатации
- Timberk swh me2 10 vu Инструкция по эксплуатации
- Timberk swh me2 10 v Инструкция по эксплуатации
- Timberk dh tim 50 e9 Инструкция по эксплуатации
- Timberk dh tim 40 e9 Инструкция по эксплуатации
- Timberk dh tim 30 e9 Инструкция по эксплуатации
- Timberk dh tim 25 e7 Инструкция по эксплуатации
- Timberk dh tim 20 e7 Инструкция по эксплуатации
- Timberk dh tim 10 e5 Инструкция по эксплуатации
- Timberk swh fsl1 100 ve Инструкция по эксплуатации
- Timberk swh fsl1 80 ve Инструкция по эксплуатации
- Timberk swh fsl1 30 ve Инструкция по эксплуатации
- Timberk swh fsl1 50 ve Инструкция по эксплуатации
- Timberk swh fsl2 80 he Инструкция по эксплуатации
- Timberk swh fsl2 100 he Инструкция по эксплуатации
- Timberk swh fsl2 50 he Инструкция по эксплуатации
- Timberk swh fsl2 30 he Инструкция по эксплуатации
- Timberk tch a8c 4000 Инструкция по эксплуатации