.7 Information for the installation
technician
Before starting up the machine, check that
it has been correctly installed and commis-
sioned (test report).
1. Check that there are no gas leaks from
weldings or joints made during installa-
tion works.
2. Check that the pipes connecting the
condenser to the remote condensing
unit have been well insulated.
3. Check all wiring connections.
4. Check electrical input.
5. Check the standard pressure in the
refrigerant system.
6. Check the water connections and effi-
ciency of the pressure switch valve dur-
ing operation, as well as the flow of con-
densing water (in water-cooled units).
7. Perform at least one blast freezing cycle
(to the SET temperature) and one manu-
al defrosting cycle.
In the event that the appliance or the
remote condensing unit have not been
transported in a vertical position (e.g. on
the back) or have been overturned during
installation works, allow at least 4 hours
before starting up the equipment.
• Inform the customer of the exact purpose
of the appliance, with specific reference
to the use and requirements of the cus-
tomer.
The appliance must be installed and put
into service by a technician authorised.
2.8 Safety and control systems
• Door microswitch: shuts down fan opera-
tion in the cell when the door is opened.
• General fuses: protect the power circuit
against short circuiting and overloads.
• Compressor heat relay: intervenes in the
event of overloads or operating faults.
• Safety pressure switch: intervenes in the
event of excessive pressure in the refrig-
erant circuit.
• Plug fuses: intervene in the event of over-
pressure or operating fault in the safety
pressure switch (see above).
• Chamber temperature control: operated
by the electronic board by means of a
probe inside the cell.
• Temperature control end defrost cycle:
controlled by the electronic board by
means of the probe in the evaporator.
2.9 Disposal of waste electronic
and electrical equipment (WEEE)
Fulfilling Directives 2002/95/CE,
2002/96/CE and 2003/108/CE on the dispo-
sal of waste electronic and electrical
equipment.
The crossed out wheeled bin sym-
bol indicates the product must be
collected separately from other
waste when it has become redun-
dant. Differentiated collection of
this equipment is arranged and
handled by themanufacturer.
Consequently, the user who is wanting to
dispose of this equipment must contact the
manufacturer and follow the method the lat-
ter has adopted to allow separate collection
of the redundant equipment.
Appropriate differentiated collection for the
subsequent recycling, treatment and eco-
friendly disposal of the dismantled equip-
ment prevents possible negative effects on
the environment and health and facilitates
the recycling of materials used in manufactu-
ring the equipment.
Administrative sanctions foreseen by the
regulations in force shall be applied for any
abusive disposal of the product by the hol-
der.
Содержание
- General documentation 5
- Installation 6
- Advice to ensure efficient appliance operation 9
- Description of the vertical control panel 10
- Blast freezing cycle 18 c 11
- Chilling freezing cycle indicator led 11
- Cycle start stop 11
- Decrease value 11
- Defrosting forced ventilation 11
- End cycle by time probe temperature 11
- Haccp and printer optional 11
- Hard blast chilling cycle 3 c 11
- Increase value 11
- On off stand by 11
- Probe chilling indicator led 11
- Push button 11
- Recipe programs chilling cycles 11
- Soft blast chilling cycle 3 c 11
- Sterilization by uv c lamp optional 11
- Storage indicator led 11
- Temperature display 11
- Time display 11
- Timed chilling indicator led 11
- Programming and operating instructions 12
- Additional functions 18
- Appliance functions 18
- User parameter settings 21
- Alarm management 22
- Alarm relays remain activated as long as the alarm is displayed 26
- During alarms the beeper is activated and the display shows the message all xx 26
- In the case that more than one alarm has been activated each one is alternately displayed 26
- Information on alarms 26
- List of other operating faults not indicated 26
- Power failures will not erase current alarms 26
- The alarm message is alternated on the display even when the beeper has been silenced until the alarm has been cleared 26
- When the beeper is activated the operator can silence it by pressing the relative push button after which the alarm can be cleared by pressing the beeper reset button again 26
- Maintenance and cleaning 27
Похожие устройства
- Castel MAC E15-40 Сертификат
- Smeg CW511MDA-2 Инструкция по эксплуатации
- Smeg CW511MDA-2 Подключение дозаторов к посудомоечной машине
- Smeg LEV 143 XV Инструкция по эксплуатации
- Robot Coupe R402 220В (без дисков) Инструкция по эксплуатации
- Robot Coupe R402 220В (без дисков) Сертификат
- Robot Coupe R402 220В (без дисков) Каталог оборудования Robot Coupe
- Airhot MM-11 Инструкция по эксплуатации
- Airhot MME-11 Инструкция по эксплуатации
- Airhot MME-20 Инструкция по эксплуатации
- Lainox NLV084 Инструкция по эксплуатации
- Starfood 201L Инструкция по эксплуатации
- Starfood 130L-2 Инструкция по эксплуатации
- Starfood Savoye (гладк. пов.) Инструкция по эксплуатации
- PANERO SF600V-1400 Инструкция по эксплуатации
- KitchenAid 5KEK1522EER красный Инструкция по эксплуатации
- KitchenAid 5KEK1522EOB черный Инструкция по эксплуатации
- KitchenAid 5KEK1522ECA карамельное яблоко Инструкция по эксплуатации
- KitchenAid 5KEK1522EGA зеленое яблоко Инструкция по эксплуатации
- KitchenAid 5KEK1522EFP морозный жемчуг Инструкция по эксплуатации