5.1. Base station
•Use the base (22) to position the base station on alevel
surface.
•Alternatively,you can install the base station on awall
using the opening (21) on the back.
5.2. Measuring station
•You can fasten the measuring station horizontally or
vertically to an outer wall using amounting plate (25).
•Ifyou want to mount the measuring station horizontally,
use rawl plugs, screws, etc. to fasten the mounting plate
(25) using the central cut-out (27) to the wall intended
for installation.
•Ifyou want to mount the measuring station vertically,use
rawl plugs, screws, etc. in the wall intended for installation
and hang the mounting plate (25) using cut-out (26).
•Gently push the measuring station until you hear alatching
sound (“click”) as it engages with the clips (28).
6. Operation
Note –Input
Hold down the button (16) or the button (14) to
select the values faster.
6.1. Connection to the measuring station
•After you insert the batteries, the base station automatically
searches for aconnection to the measuring station and
performs initial setup.
Note
•Initial setup takes approx. 2minutes.
•During connection, the wireless symbol on the
measuring station will ash (1).
•Donot press any buttons during setup. Otherwise,
values may not be transmitted correctly and thereisa
risk of value errors and inaccuracies.
•The setup process is completed when the indoor (4)
and outdoor (3) measurement data is displayed.
•The measured value is automatically updated by the
base device about every 45 seconds.
•Ifthe temperatureisoutside of the measuring range,
--.- (lower than minimum temperature) or --.- (higher
than maximum temperature) willappear on the
temperaturedisplay.
•Ifthe base station still does not receive asignal from the
measuring station, press and hold the button (14) for
approx. 3seconds to start the manual search for th
Display
Search for asignal from the
measuring station
Display ashing
Active
Displayed continuously
Successful
signal is being received
Displayed continuously
Inactive
no signal reception
Note –Faulty transfer of measured values
•Inisolated cases, interference -e.g. from aWLAN
network, acomputer or atelevision set -can cause the
transfer of measured values between the measuring
station and the base station to fail.
•Inthis case, you must resynchronise the stations by
briey removing the batteries from both stations and
reinserting them.
•Ifthe measured values arenot transferred again once
the batteries areinserted, replace the batteries with
new ones.
•Ifnecessary,select anew location for the base station
in order to avoid possible interference in the future.
6.2. Selecting the channel/other measuring stations
Note
•You can installtwo moremeasuring stations in addition
to the included measuring station. Ensurethat the base
and measuring stations areset to the same channel.
Visit www.hama.com for suitable measuring stations.
•The transmission channel on the supplied measuring
station cannot be changed/set (CH1).
•Press the CHANNEL button (15) repeatedly to set the
channel to that set on the respective measuring station.
CH1, CH2 or CH3 (2) is displayed.