5.5 Please install supports as are shown in Figure 4.1 for operation of convector on a floor.
5.6 Set the key of the switcher (keys of the power regulator) to ―0‖ position, set the handle of the thermos-
tat into position. The convector is ready for operation.
6 ORDER OF OPERATION
6.1 Connect the convector card plug to the power socket. Pres the switch key to ―I‖ position (keys of the
power regulator to ―I‖+‖II‖ position). Set the handle of the thermostat to the scale value close to the value ―6‖.
Wait a few hours for the temperature to stabilize.
When the temperature in the room reaches the desired value (you can check the temperature by means of
a thermometer) leave the control handle in this position.
If the temperature does not suit you change the position of the control handle. This temperature will be au-
tomatically maintained in the room later on.
6.2 Operation in the model of the room protection from freezing.
This mode is used to keep the temperature at approximately 7°C in the room when you are absent from the
house for a prolonged period (i.e. more than 24 hours).
Set the switch key to position ―I‖ (keys of the power regulator to position ―I‖+‖II‖). Set the thermostat handle
into position . The convector nice automatically maintain the temperature in the room at the plus level
(5…7) C, this protects the room from freezing.
6.3 Disconnection of the connector from the mains set the switches keys to the switched off position ―0‖, set
the thermostat handle to the position with the designation and disconnect the power cord plug from the
mains socket.
6.4 Recommendations for use:
- there is no point in setting the unit to this maximum, the room temperature will not rise any faster;
- When you air the room, disconnect the convector by putting the switch to ―0‖.
- If you leave for several hours, remember to reduce the temperature.
Absence for:
- less than 2 hours, do not touch the controls.
- 2 to 24 hours, lower the thermostat handle by two graduations or set the one of switches to ―0‖ position.
- more than 24 hours or in the summer, set the thermostat handle to position (Frost Free mode)..
- If you have several units in a room, let them operate simultaneously.
This will give you a more uniform temperature without increasing electricity consumption.
7 MAINTENANCE
To maintain performances of your unit, you should clean the upper and lower grilles of the unit about twice
a year using a vacuum cleaner or a brush.
Dirt may collect on the grille of the unit if the atmosphere is polluted. This phenomenon is due to the poor
quality of the ambient air. In this case, it is recommended to check that the room is well ventilated (ventilation,
air inlet, etc.), and that the air is clean. The unit will not be replaced under the guarantee because of this type
of dirt.
The unit casing should be cleaned with a damp cloth, never use abrasive products.