Timberk TEC.PF1 M 2000 Инструкция по эксплуатации онлайн [4/10] 331303
Содержание
Похожие устройства
- Timberk TEC.PS1 LE 2500 Инструкция по эксплуатации
- Timberk TEC.E2 E 2000 Инструкция по эксплуатации
- Timberk TEC.E2 E 1500 Инструкция по эксплуатации
- Timberk TEC.E2 E 1000 Инструкция по эксплуатации
- Jacob Delafon ODEON UP E4710-00 Инструкция по эксплуатации
- Jacob Delafon ODEON UP 18558W-00 Инструкция по эксплуатации
- Jacob Delafon OVE E1585-00 Инструкция по эксплуатации
- Ricci HMAH-6 Инструкция пользователя
- Ariston UNOBLOC G 64 RI MET Инструкция по эксплуатации
- Timberk TEC.PF1 M 1000 Инструкция по эксплуатации
- Timberk TEC.PF3 LE 1500 Инструкция по эксплуатации
- Timberk TEC.PS1 EL 10 IN (RB) Инструкция по эксплуатации
- Fubag IN 206 LVP Инструкция по эксплуатации
- Fubag IWS234/680 100111 Инструкция по эксплуатации
- Барс Profi MIG-507 DT2 Инструкция по эксплуатации
- AEG WKL 503 S Инструкция по эксплуатации
- Stiebel Eltron CS 20 Инструкция по эксплуатации
- Metabo Basic 250-24 W (601533000) Инструкция по эксплуатации
- AEG WKL 753 S Инструкция по эксплуатации
- Барс Profi ARC-187 D Инструкция по эксплуатации
llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll Illlllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllin llllllllllllllllll ENGLISH 7 Control of the convector TEC PF1 M IN series convectors are equipped with a mechanical thermostat TEC PF1 E IN series convectors are equipped with a high precision electronic thermostat TEC PF1 M IN series control panel Fig 6 1 HEAT and POWER indicator light a Green POWER light is illuminated when the unit is connected to electric mains b Red HEAT light is illuminated when the unit s heating is on 2 Heating power mode selector It is used to select the following heating power modes low power Energy Save medium power Normal and high power Express Heat 3 Ionizer switch Ionizer It is used to switch on off the air ionizing function 4 Thermostat handle It is used to setthe desired room temperature Operation of the convector 1 HEAT and POWER indicator light a Green POWER light is illuminated when the unit is connected to electric mains b Red HEAT light is illuminated when the unit s heating is on 2 Heating power mode selector It is used to select the following heating power modes low power Energy Save medium power Normal and high power Express Heat 3 Ionizer switch Ionizer It is used to switch on off the air ionizing function 4 Thermostat handle It is used to setthe desired room temperature 1 Switch on the convector Connect the convector to electric mains by plugging the power cord into an electric outlet at that a green POWER indicator light will be illuminated on the control panel 2 Select heating power With the help of the heating power mode selector set the required heating power low power Energy Save medium power Normal high power Express Heat 3 Set temperature Turn the thermostat handle clockwise to the stop at that if room temperature is below the set one then the red HEAT indicator light must be illuminated When the room temperature reaches the desired level turn the thermostat handle counterclockwise until the unit is switched off the red HEAT indicator light will go out Now the thermostat will maintain the set temperature switching on and offtheconvectorfromtimeto time During especially cold weather the convector may not be able to provide the required room heating In this case set the thermostat to the level somewhat higher than the desired one TEC PF1 E IN series control panel Fig 7 Comfort mode which can be selected by means of the thermostat handle corresponds to the most comfortable room temperature 5 Air ionizing function The convector is equipped with an air ionizer 5 1 You can switch on and off the air ionizer by means of an ionizer switch ionizer located on the control panel 5 2 Ionizer switch illumination lights up when the air ionizer is switched on 5 3 The air ionizer is a completely independent device and can operate even when the unit s heating mode is off Operation principle Principle of operation of the ionizer is generally reduced to the fact that under high voltage applied to metal needles with diameter of the point equal to 5 10 m there is electron flowing off electric efflux Molecules of air oxygen capture these electrons receiving a negative charge and become negative air ions thus a high concentration of light negative air ions of oxygen is generated in the air The Ionizer is designed for sanitation and prevention of different diseases to reduce fatigability to improve ability to work and immunity to clean air from airborne pollutions allergens and microorganisms to neutralize harmful impact of operating computers TV sets office equipment on man to restore biological activity of the air coming to a room through air conditioners filters air ducts to create a comfortable environment and good mood Besides air ionizers are intended to clean the air from tobacco smoke smells resins dust pollen plant spores animal hair viruses and bacteria Air ionizers will help to preserve your health prevent infectious diseases allergies and create a comfortable environment at home and or in the office Applied air ionizer complies with the current SanPiN dated 2003 Values of rated indices of air ion concentrations and the unipolarity coefficient are given inTable 4 as per SanPiN 2 2 4 1294 03 6 Switch off the convector Set the power mode selector to position OFF and disconnect the unit from electric mains at that the POWER indicator light on the control panel will go out 8 Maintenance The unit must be cleaned regularly to remove dust and dirt from external surfaces since it affects its operation efficiency and temperature parameters of room heating Prior to preventive operations switch off the unit and disconnect it from electric mains let it cool down then wipe its surface by a soft and slightly damp duster It is not recommended to use detergents for washing including materials with abrasive elements Prevent damaging the unit by sharp objects since scratches on a painted surface may cause rusting Rear surface of the convector must also be regularly cleaned from dust and dirt For this purpose it is necessary to dismount the unit from the bracket and after cleaning it is necessary to return it to the initial position Preventive cleaning should be performed regularly to maintain technical condition of the convector and preserve its external appearance for a long time Table 4 Rated indices Concentration n ion cm3 illlllllllllllllttlllllllllllllllllllllllllllllill 4 Antifreeze mode Turn the thermostat handle counterclockwise to position J The thermostat will automatically switch on heating of the convector if the room temperature goes below 5 C and the unit is connected to electric mainsand the heating mode is on 6 www timberk ru electric convector Minimum permissible N 400 Maximum permissible n 50000 n 400 0 4 Y 1 0 n 50000 www timberk ru electric convector 7