Telwin Geminy 11 Инструкция по эксплуатации онлайн [3/56] 413817

Telwin Geminy 11 Инструкция по эксплуатации онлайн [3/56] 413817
5. OPERATION voltage over the battery terminals. When this
BEFORE CHARGING voltage reaches 14.4 / 28.8 Volt (this can be easily
NB: Before charging check that the capacity of detected by a normal tester) it is advisable to
the battery (Ah) which is to be charged, is not stop charging.
inferior to that reported on the data plate. (C ________________________________________
min).
Follow the instructions, taking great care to
END OF CHARGING
- Disconnect the power supply to the battery
respect the order given below.
charger by disconnecting the cable from the
- Remove the caps of the battery (if present) to
mains outlet.
allow release of the gases produced during
- Disconnect the black charge clamp from the
charging.
chassis of the vehicle or from the negative
- Check that the level of the electrolyte covers the
terminal of the battery (- symbol).
plates of the battery. If these are not covered add
- Disconnect the red charge clamp from the positive
distilled water and cover them up by 5-10 mm.
terminal of the battery (+ symbol).
________________________________________
- Store the battery charger in a dry place
- Close up the battery cells with the appropriate
WARNING: TAKE THE GREATEST CARE
caps (if present).
D U R I N G T H I S O P E R AT I O N A S T H E
ELECTROLYTE IS A HIGHLY CORROSIVE ACID.
6.
________________________________________
The battery charger is equipped with safety cutouts
Please remember that the exact charge status of the
that trigger in the event of:
battery can only be determined by using a
- Overload (too much current delivered towards the
densimeter which allows measurement of the
battery).
specific gravity of the electrolyte; the following
- Short circuit (charging clamps set in contact with
indicate approximate density values for the solute
one another)
(Kg/l at 20°c):
- Inversion of polarity on battery terminals.
1.28 = charged battery
For battery chargers equipped with fuses, it is
1.21 = half-charged battery
necessary, in case of substitution of fuses, to use
1.14 = flat battery
spares having the same nominal current value as
- Check the battery voltage and make sure that the
the fuse changed.
settings on the battery charger panel are
________________________________________
compatible with the specifications for the battery
to be charged.
WARNING: If fuses with current values
- Check the polarities of the battery terminals:
different from those given are used this could
positive for the + symbol and negative for the -
cause damage to people or objects. For the
symbol.
same reason never, ever, substitute the fuse with
NOTE: if the symbols are indistinguishable
a copper (or other material) bridge.
remember that the positive terminal is the one not
connected to the vehicle chassis.
The substitution of the fuses is to be done when
- Connect the red charge clamp to the positive
the mains cable is DISCONNECTED from the
terminal of the battery ( + symbol).
mains.
- Connect the black charge clamp to the vehicle
________________________________________
chassis, at a safe distance from the battery and
the fuel pipe.
7. USEFUL ADVICE
NOTE: if the battery is not installed in the vehicle,
- Clean the positive and negative terminals of
connect the clamp directly to the negative
possible oxidation so as to ensure good contact
terminal of the battery (- symbol).
with the clamps.
- Never ever allow the two clamps to come into
CHARGING
contact when the battery charger is plugged into
- Power the battery charger by inserting the power
the mains.
supply cable in the mains outlet.
- If the battery charger is used with a battery which
_____________________________________________
is always connected to a vehicle, check the
instruction and/or maintenance manual of the
vehicle under the paragraph: “ELECTRIC
WARNING: SEALED BATTERIES.
SYSTEM” or “MAINTENANCE”. Before charging
If you need to charge this type of battery, be most
it is advisable to disconnect the positive cable
careful. Charge slowly and keep on checking the
which is part of the electrical system of the
BATTERY CHARGER PROTECTIONS
3

Содержание

Похожие устройства