Fluke 2042 Инструкция по эксплуатации онлайн [28/28] 4556
![Fluke 2042 Инструкция по эксплуатации онлайн [28/28] 4556](/views2/1005084/page28/bg1c.png)
Technical Data
Transmitter:
Outputsignal....................................125 kHz
External voltage detection
Voltage Range ................................12...400 V
Frequency Range............................0...60 Hz
Display ............................................LCD with display of functions
External Voltge Detection ..............max. 400 V AC/DC
Over Voltage Category....................CAT III/300 V
Pollution Degree..............................2
Power Supply..................................6 x 1,5 V, IEC LR6
Power Consumption........................max. 40 mA
Fuse................................................F 0.5 A 500V, 6.3 x 32 mm
Temperature
Range (Work)..................................0...40°C, max 80% rel.humidity (not condens.)
Temperature Range (Storage) ........-20...+60°C, max 80% rel. humidity (not condens.)
Height above MSL ..........................up to 2000 meters
Dimensions ....................................190 x 85 x 50 mm
Weight ............................................approx.260 g (without battery)
........................................................approx. 400 g (with battery)
Receiver:
Tracing depth ..................................The tracing depth depends of medium and application
Cable Locator Mode........................approx. 0...2 meters (single-pole application)
........................................................approx. 0...0.5 meters (double-pole application)
Voltage detection ............................approx. 0...0.4 meters
Display ............................................LCD with functions- and bargraph
Power Supply..................................1 x 9 V, IEC 6LR61
Power Consumption........................approx. 17 mA (without backlight or lamp)
........................................................approx. 50 mA (with backlight)
........................................................max. 70 mA (Backlight and lamp)
Temperature Range (Work) ............0...40°C, max 80% rel. humidity (not condens.)
Temperature Range (Storage) ...... -20...+60°C, max 80% rel. humidity (not condens.)
Height above MSL ..........................up to 2000 meters.
Dimensions ....................................250 x 65 x 45 mm
Weight ............................................approx.220 g (without battery)
........................................................approx. 270 g (with battery)
28
Fluke 2042
Technical Data
Похожие устройства
- LG MS-2354G Инструкция по эксплуатации
- DBX 1066 Инструкция по эксплуатации
- Belkin Home Theater Power PF50 Black Инструкция по эксплуатации
- LG F-1029SDR Инструкция по эксплуатации
- LG MS-2352U Инструкция по эксплуатации
- Fluke 233 Инструкция по эксплуатации
- Ada BASIS А00117 Инструкция по эксплуатации
- Belkin AV10009qp1M Инструкция по эксплуатации
- DBX 166XSV Инструкция по эксплуатации
- LG F1056ND Инструкция по эксплуатации
- Fluke 27 Инструкция по эксплуатации
- LG MS-2352T Инструкция по эксплуатации
- Ada 6D Maxliner А00138 Инструкция по эксплуатации
- Supra SFD-115U Инструкция по эксплуатации
- DBX DRIVERACK PA+ 2X6 Инструкция по эксплуатации
- Belkin AV10009qp2M Инструкция по эксплуатации
- LG E1069SD Инструкция по эксплуатации
- Supra SFD-111U Инструкция по эксплуатации
- Blue Weld Combi 132 821340 Инструкция по эксплуатации
- Fluke 27II Инструкция по эксплуатации