5. GENERAL SAFETY PRECAUTIONS
Before operating the electropump, the user should
know how to perform all operations described in
this manual and apply them every time during the
use or maintenance of the electropump.
The user must strictly observe the safety regulations
in force in his country; he must also take into
account the electropump features (see "data label").
The user must never carry out operations or
interventions, which are not accepted in this manual,
on his own initiative.
This device is not intended for use by persons
(including children) with reduced physical, sensory
and mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of this device by a
person responsible for their safety.
During the repair or maintenance interventions of
the electropump, take off the power supply, thus
preventing the accidental starting that could cause
damage to persons and/or property.
Any maintenance, installation or moving operations
performed on the electropump with the electric
system energized, can cause serious accidents
or death to persons.
Do not start the unit when barefoot ,or worse, in
water and with wet hands.
5.1. INTENDED USE
The circulating pumps Ego (ER) -/40, Ego (ER) -/60, and
Ego (ER) -/80 are designed for forced circulation of the
fluid in central heating systems. They differ from standard
fixed speed pumps by having the option of continuous
adjustment of the pump operation to the actual needs of
the system. This feature gives both great electrical and
thermal saving together with reduced noise level in the
installation. In order to guarantee a regular operating of
the pump, a fluid which is appropriate for a central heating
system, such as pure water or a solution of pure water and
antifreeze, must be provided. The water must meet water
quality standards, such as VDI 2035. Use the electropumps
according to their specification.
5.2 NOT INTENDED USE
All uses not specifically mentioned in 5.1 are generally
banned; in particular, the fluid must not contain aggressive
or explosive additives, mixtures of mineral oils and/or solid
or fibrous particles. The pump should not be used for
pumping flammable or explosive media, or in an explosive
atmosphere. To avoid formation of condensation in the
pump, fluid temperature must be higher or equal to the
ambient temperature.
6. TECHNICAL AND BUILDING FEATURES
6.1 TECHNICAL DATA
Supply voltage: 230V, 50Hz
Protection class: IP44
Insulation class: H
USE AND MAINTENANCE
INSTRUCTION MANUAL
TO BE KEPT BY THE USER
1. INTRODUCTION
Follow the instructions contained in this manual to obtain
the best performance and the proper operation of the
electropump.
For any further information, please contact your nearest
authorized dealer.
ALL TYPES OF REPRODUCTION, EVEN PARTIAL, OF
THE ILLUSTRATIONS AND/OR TEXT IS PROHIBITED.
The following symbols have been used in the handbook:
ATTENTION
Risk of damage
to the pump or plant
Risk of damage
to persons or property
Electrical hazards
2. INDEX
1. INTRODUCTION pag. 5
2. INDEX pag. 5
3. IDENTIFICATION DATA pag. 5
4. WARRANTY AND TECHNICAL ASSISTANCE pag. 5
5. GENERAL SAFETY PRECAUTIONS pag. 5
6.
TECHNICAL AND BUILDING FEATURES p
ag. 5
7. INSTALLATION, DISMANTLING
AND TRANSPORT pag. 6
8. ELECTRICAL CONNECTION pag. 6
9. USE AND RUNNING pag. 6
10. SETTING AND OPERATING
11. MAINTENANCE AND REPAIR pag. 6
12. DEMOLITION pag. 7
13. TECHNICAL DOCUMENTATION ATTACHED pag. 7
14. TROUBLESHOOTING pag. 7
15. DECLARATION OF CONFORMITY pag. 7
16. INSTALLATION DIAGRAM pag. 23
3. IDENTIFICATION DATA
3.1. MANUFACTURER
EBARA PUMPS EUROPE S.p.A.
Factory management:
Via Pacinotti, 32 - 36040 BRENDOLA (VI) ITALIA
Telephone: Tel. +39 0444 706811 - Fax: +39 0444/405811
Registered office:
Via Campo Sportivo, 30 - 38023 CLES (TN) ITALIA
Telephone: Tel. +39 0463 660411 - Fax: +39 0463/422782
4. WARRANTY AND TECHNICAL ASSISTANCE
Failure to comply with the indications supplied in this
instruction book and/or any intervention on the unit
not performed by our assistance centres, will make the
warranty null and void and relieve the manufacturer from
any liability in case of accidents to persons or damage to
property and/or the unit itself.
Manuale_EGO - 5 lingue.indd 5 21/07/14 17.22
Похожие устройства
- Ebara Ego T 65 Технические данные
- Ebara Ego T 65 H Инструкция по эксплуатации
- Ebara Ego T 65 H Технические данные
- Ebara Ego T 80 Инструкция по эксплуатации
- Ebara Ego T 80 Технические данные
- Ebara Ego T 80 H Инструкция по эксплуатации
- Ebara Ego T 80 H Технические данные
- Casio MRS-300D-7 Инструкция по эксплуатации
- Casio MRS-300-2 Инструкция по эксплуатации
- Casio MRS-300D-7E Инструкция по эксплуатации
- Casio MRS-300-2E Инструкция по эксплуатации
- Casio MRS-300-2EVF Инструкция по эксплуатации
- Casio G-200D-1EVER Инструкция по эксплуатации
- Casio G-200D-1EVER_D Инструкция по эксплуатации
- Casio LIN-165-1B Инструкция по эксплуатации
- Casio LIN-165-8B Инструкция по эксплуатации
- Casio EDB-501-8EVR Инструкция по эксплуатации
- Casio EDB-501D-7E Инструкция по эксплуатации
- Casio EDB-500D-7AJF Инструкция по эксплуатации
- Casio EDB-501D-7AJF Инструкция по эксплуатации