Fault Possible cause Remedial action
Temperature differs
greatly from the set
value.
In some cases it is adequate to
switch off the appliance
for 5 minutes.
If the temperature is too high wait
a few hours and check whether the
temperature has approached the set
value.
If the temperature is too low check
the temperature again the next day.
Displays do not
illuminate.
Power failure; the fuse
has been switched off;
the mains plug has not
been inserted
properly.
Connect mains plug. Check whether
the power is on, check the fuses.
Freezer compartment
door was open for a
long time; temperature
is no longer reached.
The evaporator
(refrigeration
generator) in the
No Frost system is
covered in thick ice
and can no longer be
defrosted fully
automatically.
To defrost the evaporator, remove
the frozen food with the
compartments, insulate well and
store in a cool location.
Switch off the appliance and move
it away from the wall. Leave the
appliance door open.
After approx. 20 min. the
condensation begins to run into the
evaporation pan, at the rear of the
appliance. Fig. *
To prevent the evaporation pan from
overflowing in this case, mop up the
condensation with a sponge.
The evaporator is defrosted when
the water stops running into the
evaporation pan. Clean the interior.
Switch the appliance back on again.
Appliance is not
cooling, temperature
display and light
are lit.
Showroom mode is
switched on.
Hold down temperature selection
button fig. 2/4 for 10 seconds until
an acknowledgement signal sounds.
After a short time check whether
your appliance is cooling.