POWER CONNECTION HEADUNIT ENG ВАТТ Л 2V POWER Before mounting amplifiers disconnect the negative cable from the battery to protect any accidential damage to your amplifiers and audio system Connect the power cables to power terminal 12V All AurA VENOM series amplifiers are not equipped with fuses so that external fuses should be used Connect one end of fuse holder to the power cable going into the amplifiers and the other end of fuse holder to positive battery This fuse location will protect the system and the vehicle against the possibility of a short circuit in the power cable Be sure to use fuses and fuse holder adequate for the application GND GROUND Locate a secure grounding connection as close to amplifier as possible Make sure the location is clean and provides a direct electrical connection to the frame of the vehicle The ground needs to have as low of a resistance as possible Connect one end of a short piece of the same size cable as the power cable to the grounding point or to one of your batteries or battery bank Run the other end of the ground cable to the mounting location of the amplifiers for connection to the amplifiers ground terminals and connect the ground cable to the GND ground terminal REM REMOTE Run a remote turn on cable from the switched 12V source This may be a toggle switch a relay your source unit s remote trigger cables or power antenna trigger cable Connect the remote turn on cable to the REM remote terminal г