Invt CHV190-018G-4 Инструкция по эксплуатации онлайн [196/242] 471532

Invt CHV190-250G-4 Инструкция по эксплуатации онлайн [196/242] 471546
CHV190 series special inverter for crane
- 195 -
Function
Code
Name Description
Setting
Range
Factory
Setting
Modify
6:Modbus
communication
7:Profibus
communication
8:Hierarchical
multi-stage speed
P0.03
Maximum
frequency
10.00~400.00Hz
10.00~
400.00
50.00Hz
P0.04
Keypad reference
frequency
0.00Hz~P0.03 0~P0.03 50.00Hz
P0.05
Running
direction
selection
0: Forward
1: Reverse
2: Forbid reverse
0~2 0
P0.06 Carrier frequency
1.0~16.0kHz 1.0~16.0
Depend
on model
P0.07
Motor parameters
autotuning
0: No action
1: Rotation autotuning
2: Static autotuning
0~2 0
P0.08 Reserved 0~65535 0~65535 0
P0.09 Reserved 0~65535 0~65535 0
P0.10 Reserved 0~65535 0~65535 0
P0.11
Application mode
selection
0: Common application
mode
1: Operating lever mode
2: Remote Mode
3: Hierarchical operating
lever mode
4: Hierarchical remote
mode
5:
mode
6: Master-
slave power
equilibrium host mode
0~9 0