CHV190 series special inverter for crane
- 174 -
Notice:
1) Example one above is application control diagram for flexible load drive. The
master and slave are connected by belts or other extendable materials (flexible
load). Due to ductility of materials, some speed error between master and slave is
permitted.
2) The master and slave both use speed control under this situation. The host
sends the running frequency to the slave as frequency reference. At the same time,
the slave receives current output torque (output current) of the host, and then
compares with its own torque to do PID error calculation whose result will be used
as the adjustment for the slaves current frequency reference. The master and slave
can realize synchronization control and power balance at last.
3) In the master-slave control mode, the running command of the host is connected
to fault signals of the slave, once the slave is fault; the host is not allowed to run.
4) There are three types mode for PID calculations of the slave depending on
specific applications.
5) The meaning of F_m> Pb.24 is to make sure that the slave starts PID calculation
after the host starts to prevent PID initial calculation accumulation of slave before
host starting.
Example two for master-slave control:
Notice:
1) Example two above is application control diagram for rigid load drive. The
connection between the master and the slave is fixed. It should be no speed error