CHV190 series special inverter for crane
- 175 -
between the master and the slave.
2) The master use speed control and the slave use torque control under this
situation. The master sends output torque (output current) to the slave as the
torque reference. At the same time, the slave receives running frequency of the host,
and then compares with its own frequency to do PID error calculation, whose result
will be used as the slaves adjustment current torque reference. The master and
slave can realize synchronization control and power balance at last.
3) In the master-slave control mode, the running command of the host is connected
to fault signals of the slave, once the slave is fault; the host is not allowed to run.
4) There are three types mode for PID calculations of the slave depending on
specific applications.
5) The meaning of F_m> Pb.24 is to make sure that the slave starts PID calculation
after the host starts to prevent PID initial calculation accumulation of slave before
host starting.
If set P0.11=6, the master-slave power equilibrium host mode is valid when the inverter
master-slave power equilibrium control mode is host under master-slave speed control
host mode.
Digital terminal S1 and S2 control crane running up and down. If inverter receives two
directions simultaneously, it will coast to stop; keypad will not display the fault information.
Fault output of the slave should be connected to the external fault terminal of the host.
Master-slave power equilibrium host mode parameter settings are as follows:
Function code
Name Selection
Description
P0.01 Run command source 1
Terminal command
channel (LED flashing)
P0.02 Speed command source
1 AI1 setting
P1.09 Linear acceleration time
4.0s Acceleration time
P1.10 Linear deceleration time
4.0s Deceleration time
P5.01 S4, S5 input type 0 ON/OFF input
P5.02 S1 terminal function 1 Forward (FWD)
P5.03 S2 terminal function 2 Reverse (REV)
P5.04 S3 terminal function 7 External fault (EF)
P6.04 Relay 1 output 4 Fault output
P6.05 Relay 2 output 7 Brake output
P6.07 AO1 output 0 Running frequency
P6.08 AO2 output 4 Current output