Qtech QSW-8200-28T-POEAC- DC Команды для потокового монитора онлайн [11/11] 481628

Qtech QSW-8200-28T-AC-DC Команды для потокового монитора онлайн [11/11] 481627
User Manual
Chapter 3. Commands for sFlow 11
www.qtech.ru
configured
Collector port is 6343
the sFlow global destination port is the defaulted
6343
Sampler priority is 2
The priority of sFlow when receiving packets from
the hardware is 2.
Sflow DataSource: type 2,
index 194(Ethernet1/0/1)
One sample proxy data source of the sFlow is the
interface e1/0/1 and its type is 2 (Ethernet), the
interface index is 194.
Collector address is
192.168.1.200
The analyzer address of the sampling address of the
E1/0/1 interface is 192.168.1.200
Collector port is 6343
Default value of the port on E1/0/1 interface
sampling proxy is 6343.
Counter interval is 20
The statistic sampling interval on e1/0/1 interface is
20 seconds
Sample rate is input 10000,
output 0
The ingress traffic rate of e1/0/1 interface sampling
proxy is 10000 and no egress traffic sampling will be
performed
Sample packet max len is
1400
The length of the sFlow group data sent by the
e1/0/1 interface should not exceed 1400 bytes.
Sample header max len is 50
The length of the packet data head copied in the
data sampling of the e1/0/1 interface sampling
proxy is 50
Sample version is 4
The datagram version of the sFlow group sent by the
E1/0/1 interface sampling proxy is 4.

Похожие устройства